Technical Guide: RDMS Telnet and Serial Control
64
Quasonix, Inc.
Examples:
PL M 0
Set the power level measurement type to Total Power
PL M 1
Set the power level measurement type to Signal Power
PL S
–
Sets the power level scale value
Example:
PL S 2.517
Set the power level scale value to 2.517
Valid range is 0.000 to 7.996
2.1.1.37 Phase Noise Compensation - PNC
The PNC command reports or sets the phase noise compensation state.
PNC [<m>|D <d>|H <h>]
<m> - Sets phase noise compensation mode to <m>
where: <m> - Mode
0 - Disabled
1 - Enabled
A - Automatic
D <d> - Sets auto phase noise compensation deadband to <d>
H <h> - Sets auto phase noise compensation hysteresis to <h> ms
Examples:
PNC
Phase noise compensation off
PNC 0 Set phase noise compensation to Off
PNC 1 Set phase noise compensation to On
2.1.1.38 Query Temperature - QT
The Query Temperature command reports the temperature in degrees Celsius.
Example:
QT
FPGA temperature: 41.0
°
C (85
°
C Max)
Demod temperature: 43.0
°
C (85
°
C Max)
2.1.1.39 Signal Degradation Information - SDI
The Signal Degradation Information command sets and displays a variety of signal degradation information settings.
SDI [<e>|T <e>|S <s>|P <p>|L <l>|IT <t>|ET <t>]
<e> - Sets the SDI enable to <e>
where: <e> - Enable