Technical Guide: RDMS Telnet and Serial Control
14
Quasonix, Inc.
Mnemonic
Name
Description
Option (s)
Required
Mode
Restriction
VE
Version
Report the current Firmware
(software) version
information for the receiver;
displays the current
application, FPGA, and
adaptive equalizer versions
Standard
None
2.1.1
Additional Command Set Details
2.1.1.1
Commands Used with AQPSK or AUQPSK Modes
The commands detailed below generally operate on a single data stream. AQPSK and AUQPSK modulation,
however, contain two data streams that require different bit rate settings and may require other independent settings.
As a result, when using AQPSK or AUQPSK modes, some command components require a datapath parameter to
distinguish which stream is being configured. These commands include: Best Channel Selector (BCS), Clock and
Data Polarity (CP, DP), Derandomizer (DR), Data Quality (DQ), Forward Error Correction (FEC), and PCM
Decoding (PDC).
Refer to the receiver Help for the syntax specific to each command.
For example:
BCS
in
AQPSK mode
Displays and controls best channel selector settings
BCS [<d><e>]
–
Sets best channel selection enable for data <d> to <e>
where:
<d> - Datapath component
A
–
Data A
B
–
Data B
<e> - Enable
0
–
Disabled
1
–
Enabled
All of the commands follow a similar pattern, however,
not all components of a particular command contain the
datapath parameter
. In the following BCS example, the BCS Source controls the enables for both BCS channels:
BCS [S<s><e>]
- Sets best channel selector source <s> enable to <e>
where:
<s> Sources
CH0
–
Channel 0