Fuse
Fuse Holder
Fuse Holder flush with AC power receptacle
Figure 3-3 Fuse Holder on rear of Library
Whenever you pull out the fuse holder and push it back in order to replace or check
the fuse, be sure to push it to the point where the AC power receptacle and the fuse
holder are flush with each other.
3.3.3
Power Cord
The supplied detachable power cord complies with the following specifications:
•
100-120 volt
applications
UL listed and CSA certified three-conductor 18 AWG SJT vinyl-
jacketed cord. One end is terminated with an IEC 320 C13 style
connector. The other end is terminated with a NEMA 5-15P type plug.
•
200-240 volt
applications
Harmonized three-conductor HO5VV F3G 1.0mm vinyl-jacketed cord.
One end is terminated with an IEC 320 C13 style connector. The other
end is terminated with the European CEE7 Standard VII type plug.
3.4
Temperature, Humidity and Altitude
PARAMETER OPERATING
NON-OPERATING
{
Ambient temperature
+5°C to +32°C
(+41°F to +90°F)
-20°C to +60°C
(-4°F to +140°F)
Temperature gradient
(maximum)
1°C°/minute, 10°C/hour
(2°F/minute, 18°F/hour)
1°C/minute, 20°C/hour
(2°F/minute, +36°F/hour)
Relative humidity
(non-condensing)
20% to 80%
10% to 90%
Wet bulb temperature
26°C (79°F) maximum
29°C (84°F) maximum
Altitude
-1000 to +10,000 feet
-304.8 to +3,048 meters
-1000 to + 40,000 feet
-304.8 to +12,192 meters
{
Includes tape drives
Table 3-5 Environmental Specifications
511000 Rev. F
Specifications 3-5