background image

QuadroM32x Manual I: Installation Guide 

Step 2: Configuring the Quadro 

 

 

Fig. I-30: Trunk T1 Signaling Type CCS - B-Channels page  

Channel Selection drop down list is used to select between the Preferred and Exclusive 
B channel selection methods. For Preferred channel selection, the CO answers to the call 
request by the first available timeslot, while for Exclusive channel selection CO should 
feedback only by the timeslot used for the call request. 

 

Channel Selection Ordering drop down list is used to choose the B channels selection 
(Ascending or Descending). When Ascending selection is configured, B channels will be 
defined starting from B1 to B23/B30. For Descending selection, B channels will be defined 
from B23/30 to B1. If your CO/PBX has Ascending B channels selection configured, it is 
recommended to use Descending B channels selection and vice versa. 

Please Note:

 A timeslot can be used either for voice or data transfer. The system prevents 

selecting a timeslot from the B channel list if it has already been selected from the D Chan-
nel receive/transmit drop down list. 

 

Edit will display the first page of the CAS signaling Wizard page (see below), which con-
tains 3 checkboxes: 

 

Enable Timeslot – used to enable/disable the selected timeslot(s); 

 

Force Update Timeslot – used to apply new settings immediately by restarting 
the timeslot(s); 

 

Enable Echo Cancellation – used to enable/disable the echo cancellation fea-
ture on the selected timeslot(s). 

 

 

 

QuadroM32x; (SW Version 5.2.x)

 

35 

Содержание QuadroM32x

Страница 1: ......

Страница 2: ...Please direct all inquiries to Epygi Technologies Ltd Two Legacy Town Center 6900 North Dallas Parkway Suite 850 Plano Texas 75024 Representative in Brazil Saga Sistemas e Computadores SA Av Rio Bran...

Страница 3: ...terface Use caution when installing or modifying cable or telephone lines Avoid using your Quadro during an electrical storm Do not use your Quadro or telephone to report a gas leak in the vicinity of...

Страница 4: ...s 18 Emergency and PSTN Access Code Settings 19 Finishing the System Configuration Wizard 20 Step 2 3 Internet Configuration Wizard 21 Uplink Configuration 22 WAN IP Configuration 23 PPP PPTP Configur...

Страница 5: ...the menus available for administrators only Fur thermore it includes all the system s default values at a glance Manual III see Extension User s Guide This guide describes in detail the menus availabl...

Страница 6: ...scribes the configuration steps necessary to integrate the Quadro into your network environment Step 2 A Using IP Lines explains how to configure IP lines on the Quadro IP PBX and to connect IP phones...

Страница 7: ...11 telephone cable At least one IP phone with CAT5 cable with RJ45 connector Two CAT 5 Ethernet cables with RJ45 connectors to connect to the Quadro s ETH and LAN ports One PC with a 10 100 Mbps Ether...

Страница 8: ...he administration password you entered Please Note A Factory Reset forces the default LAN IP address of 172 30 0 1 and default admin password of 19 3 RJ 45 socket to attach the E1 T1 trunk See Appendi...

Страница 9: ...during a firmware update A firmware update is indicated by the red Fault and yellow Info LEDs Both will blink si multaneously for about two minutes while the firmware is being updated The Quadro will...

Страница 10: ...ess that remains valid until changed If you plan to use the Quadro as your Internet access router contact your Internet Service Provider ISP to find out if a static IP address is assigned to your acco...

Страница 11: ...a DHCP client on the WAN port The IP phones are placed on the WAN side of the QuadroM32x connected to the company LAN The Admin PC can be connected to the Quadro ETH or WAN port to access the Web Man...

Страница 12: ...x IP PBX used as an Internet Access Router connected di rectly to the Internet Fig I 5 Configuration QuadroM32x used as Internet Access Router The Admin PC is connected to the Quadro ETH port or WAN p...

Страница 13: ...to WAN Fig I 6 Installation QuadroM32x behind a router with IP phones on WAN QuadroM32x behind a router with IP phones connected to LAN Fig I 7 Installation QuadroM32x behind a router with IP phones o...

Страница 14: ...tor Connect the WAN port of the Quadro to the Internet service via a cable or DSL modem Power up the DSL or Cable modem first Connect the power cable to the POWER port on the back side of your QuadroM...

Страница 15: ...l hear a voice message that confirms you have successfully established an IP call If this call is not successful go to Appendix Checking the Connections for troubleshooting You may customize the follo...

Страница 16: ...P server in the address field of your browser If the PC is connected to the Quadro s LAN side enter http 172 30 0 1 Quadro s default LAN IP address in the address field of your browser The Login page...

Страница 17: ...left unchanged if their meanings are not completely understandable to the party administrating the Quadro System Configuration The first page of System Configuration Wizard shows all items to be confi...

Страница 18: ...unpredict able network behavior can occur Fig I 12 DHCP Settings for the LAN Interface page Click on Next to display the Regional Settings page Regional Settings If your Quadro is located outside of...

Страница 19: ...codes into the appropriate field For example in the United States the emergency number is 911 whereas in Germany it is 112 110 In case of an emergency you can then pick up any FXS phone and dial your...

Страница 20: ...ings Fig I 17 Confirm Settings page Please Note You must confirm the settings within 20 minutes Otherwise the device will revert back to the previous configuration and reboot Please Note If you do not...

Страница 21: ...h is available upstream and downstream WAN IP Configuration is DHCP supported If yes no more information is needed If DHCP is not supported the following data is needed the WAN IP address the sub net...

Страница 22: ...ervice in the United States typical values are 300 for Upstream and 1500 for Downstream The Min Data Rate text field is used to specify the amount of bandwidth reserved for data applications The value...

Страница 23: ...tomatically by the ISP This is common with cable modem and DSL service Assign Manually requires the administrator to enter the external IP Address the cor responding Subnet Mask and the IP address of...

Страница 24: ...ected LAN has to connect to Quadro first Always connected Quadro stays in the always connected mode This will allow Quadro always remain online in the network The IP Address Assignment field is used t...

Страница 25: ...e on the Ethernet in bytes Click Next to display the DNS Settings page DNS Settings For DNS the selection is set to Dynamically by Provider When using a static IP address fixed values must be entered...

Страница 26: ...on Wizard The Quadro will then stop internal functions and apply the changes made in the Wizard After this is complete the Quadro will display the Confirm Settings page requesting confirmation of the...

Страница 27: ...I 26 IP Line Settings page Select the SIP Phone radio button Select the SIP IP phone model from the Phone Model drop down list Insert the SIP Phone s MAC address in the corresponding fields The MAC ad...

Страница 28: ...following options are available Never the extension will never expire and will remain logged in to the public phone After the defined period of time requires the period after which the extension will...

Страница 29: ...ea tures like Paging Intercom etc may be missing in these SIP phones CISCO 7960 Snom M3 IpDialog ST201 Swissvoice IP 10S Polycom SoundPoint IP 300SIP Thomson ST 2030 SIP Polycom SoundPoint IP 330SIP B...

Страница 30: ...twork if connected to a PBX Further you are required to enter the E1 T1 settings your PSTN provider requires regard ing framing clocking signaling used and so on All these settings must be entered on...

Страница 31: ...ested from the service provider or in case of con necting to a PBX according to the settings in the PBX manual CAS signaling allows using the same timeslot both for voice and data transmission CCS sig...

Страница 32: ...e user on the PBX side may set any mode related to TEI assignment in the PBX configuration In the User Mode CO PSTN connected the TEI assignment depends on the CO PSTN settings So you have to enter th...

Страница 33: ...ions any active traffic on the timeslot s will be terminated Edit will display another page where the signaling set tings for the selected timeslots may be specified in detail Bearer Establishment Pro...

Страница 34: ...ll Ringing checkbox is selected the system will send ALERT messages to callers from the PSTN PBX on call ringing If not the system will send a PROGRESS message on receivng early media from the called...

Страница 35: ...B1 to B23 B30 For Descending selection B channels will be defined from B23 30 to B1 If your CO PBX has Ascending B channels selection configured it is recommended to use Descending B channels selectio...

Страница 36: ...coming calls from CO PBX to the Qua dro This service allows you to speed up the call establishment procedure by detecting the prefix The calls will be speed up by the timeout defined in the Incoming D...

Страница 37: ...lots checkbox can be optionally selected in order to apply new set tings immediately This will force the timeslot s to be restarted and any active connection on the selected timeslot s will be interru...

Страница 38: ...e CAS Signaling Wizard DID Direct Inward Dialing Service might be enabled on the timeslot s In User mode the Quadro cannot route incoming calls from the E1 T1 trunk to extensions if the timeslot in th...

Страница 39: ...the Signaling Type drop down list on the CAS Signaling Wizard Page 2 is different from R2 all types and is used to reconnect the call terminated by some reason e g user error network problems etc by...

Страница 40: ...ttings ANI Category drop down list appears only when R2 signaling selected from Signaling Type drop down list on the CAS Signaling Wizard Page 2 is different from R2 DTMF and is used to select the cal...

Страница 41: ...n the PBX attached to the Quadro supports this feature When this checkbox is selected and in case of incoming calls always the called destination will pay for the call Option is particularly applicabl...

Страница 42: ...eive signals The Transmit Answer Signal parameter is defined from the drop down list on this page When transmit signal is selected press Next on this page to access the R2 Receive Signal Settings page...

Страница 43: ...eb page gives you the username and password to login to the Epygi SIP Server To register you need to know the serial number of your Quadro which is located on a label on the bottom of Quadro You will...

Страница 44: ...Password functional button from the User Right Management page toolbar The Change Password page will be displayed Fig I 41 Change Password page Enter the Old Password 19 and the New Password in both t...

Страница 45: ...are not appro priate for SIP NAT traversal Please Note If you have more than one router in series between the Quadro and the In ternet the same port forwarding setup must be configured on each router...

Страница 46: ...RTP Parameters page and select Use Manual NAT Traversal Fig I 44 NAT Traversal Settings RTP Parameters Enter the WAN IP address of the router into the Mapped Host text field Set the Mapped RTP RTCP P...

Страница 47: ...d The displayed page now welcomes you and allows you to Subscribe a New Extension Fig I 46 SIP Services Welcome page Selecting Subscribe a New Extension leads you to a page where you can enter the use...

Страница 48: ...nsion number for entry into the Quadro later Save will store the entered information and conclude the basic SIP registration The follow ing page then will be displayed Fig I 48 SIP Services Your Exten...

Страница 49: ...to the Quadro and go to Extensions Management Fig I 49 Extensions Management page Select the first extension to change by clicking the appropriate checkbox and press Edit functional button The Extensi...

Страница 50: ...P Port You may leave the default entry as is Select Registration on SIP Server if you want to establish and receive IP calls Click the Save button to activate the settings Other settings of the extens...

Страница 51: ...ng IP configuration dynamically via DHCP Client DHCP Client is running Checking internet connectivity ICMP ping Gateway reached Primary nameserver reached Secondary nameserver not configured www epygi...

Страница 52: ...is shown If Quadro is placed behind a NAT router and the STUN is enabled the detected connection type and the IP address of this router s WAN port are displayed Fig I 54 SIP Registration Status page Q...

Страница 53: ...blems please send us a technical support request on the Support section of http www epygi com Please prepare a system log file and at tach it to your request To download the system logs open the Syste...

Страница 54: ...Installation Guide Appendix Checking the Connections Appendix Pin Assignment of E1 T1 Pin Signal 1 RXRING 2 RXTIP 3 N C 4 TXRING 5 TXTIP 6 N C 7 N C 8 N C Fig I 55 Pin Assignment of E1 T1 QuadroM32x...

Страница 55: ...QuadroM32x Manual I Installation Guide Appendix Checking the Connections QuadroM32x SW Version 5 2 x 55 QIG QUADRO 09 25...

Отзывы:

Похожие инструкции для QuadroM32x