CODE 30
Manual dosage
threshold
In this code it is possible to set out the weight
threshold for the manual dosage of the component,
that is the limit under which the component is manually
dosed by the user, and the weight is not measured
during the component loading.
For instance, by setting out a threshold of 5,000
grammes, all components whose loading amount is
lower than 5,000 grammes (5 kg) must be weighed
externally, and then manually loaded, because the
scale does not measure the component amount dosed
into the wagon during the loading operation. This
parameter is entered in Kg and is shown in grammes;
it usually changes according to the sensibility of the
load cells installed on the wagon.
It is possible to enter values between 1 and 100Kg.
CODE 43
TR60 channel and
power
In this code it is possible to set out the transmission
channel and power, for the connection or TR60
portable devices.
The access to this code is possible, only if in code 84:
The connection to the single device AV40-
5/AV50/AV80 is enabled
The position TR60 is enabled as MANUAL
MULTILINK
The position TR60 is enabled as AUTOMATIC
MULTILINK
It is possible to enter the following values:
RF channel: 0, 2, 4, 6
RF power: 0, 1, 2, 3
CODE 44
RF7 Encoding
In this code it is possible to configure the connection of
the scale with RF7 portable devices.
The access to this code is possible, only if in code 84:
The position RF7 is enabled as MANUAL
MULTILINK
The position RF7 is enabled as AUTOMATIC
MULTILINK
After entering the code, press
to start the
registration, and then press any key on the RF7 device
to end it.