29
FUNCTION
OPERATION
DISPLAY
SILO
(Optional)
Vibrator ON
Vibrator OFF
The parameter VIBRATOR ON determines the
presence of a vibrator for the SILO and its activation
(in seconds).
If the user set “VIBRATOR ON” on OFF, the vibrators
deactivated.
It is possible to introduce values from 0 to 99.
The parameter VIBRATOR OFF permits to set its
deactivation time in seconds.
It is possible to introduce values from 0 to 99.
SILO
(Optional)
Waiting change
If the manufacturer has activated the check of the
EMPTYING WEIGTH VARIATION through the
parameter WAITING CHANGE, it is possible to set the
time (in seconds). If the weight doesn’t change within
this time, the system shows an alarm.
It is possible to set values from 0 to 300.
SILO
(Optional)
Programmable outputs
It is possible to set the board and the outputs
associated to each SILO.
Press
the
key
to
verify
the
correct
connection/setting of the output on the board.
To access to the window
GROUPS PARAMTER
press
.
NOTE: The modification of the parameters contained
in this menu has to be carried out from specialized
staff. In fact a wrong setting can compromise the
correct functioning of the system.