Reference MVI56-DNP
♦
ControlLogix Platform
User Manual
DNP 3.0 Server
Page 150 of 171
ProSoft Technology, Inc.
July 21, 2011
OBJECT REQUEST
RESPONSE
Obj Var Description
Func
Codes
Qual
Codes
(hex)
Func
Codes
Qual
Codes
(hex)
Data
Size
(bits)
NOTES
32
0
Analog Change Event -
All Variations
1 06,
07,
08
24
Master will generate this
variation
1
32-Bit Analog Change
Event Without Time
1
06, 07,
08
129,
130
17, 28
40
Master will generate and
process this variation.
2
16-Bit Analog Change
Event Without Time
1
06, 07,
08
129,
130
17, 28
24
Master will generate and
process this variation
3
32-Bit Analog Change
Event With Time
1
06, 07,
08
129,
130
17, 28
88
Master will generate and
process this variation.
4
16-Bit Analog Change
Event With Time
1
06, 07,
08
129,
130
17, 28
72
Master will generate and
process this variation
33
0
Frozen Analog Event -
All Variations
1
32-Bit Frozen Analog
Event Without Time
40
2
16-Bit Frozen Analog
Event Without Time
24
3
32-Bit Frozen Analog
Event With Time
88
4
16-Bit Frozen Analog
Event With Time
72
40
0
Analog Output Status -
All Variations
1
06
24
Master will generate these
variations and parse the
responses. For variation 1,
only 16-bit value is stored.
1
32-Bit Analog Output
Status
1
06
129,
130
00,01
40
2
16-Bit Analog Output
Status
1
06
129,
130
00, 01
24
41
0
Analog Output Block -
All Variations
24
1
32-Bit Analog Output
Block
40
2
16-Bit Analog Output
Block
3, 4, 5,
6
17, 28
129
Echo of
Request
24
Master will generate this
variation and parse the
response
50
0
Time and Date - All
Variations
48
1
Time and Date
2
07, With
Quant=1
48
Master will generate this
variation
2
Time and Date With
Interval
80
51
0
Time and Date CTO -
All Variations
1
Time and Date CTO
129,
130
07, With
Quant=1
48
Master will process this
variation
2 Unsynchronized
Time
and Date CTO
129,
130
07, With
Quant=1
48
Master will process this
variation
52
0
Time Delay - All
Variations
1
Time Delay Coarse
129
07, With
Quant=1
16
Master will not process this
variation