33
PROMAG
STARMIX 60W - E60W - 60A - E60A - 120W - E120W
USER INSTRUCTIONS
GB
A 31 - IMPORTANT
The STARMIX pasteurizers are fitted with a self-control system, indicating eventual anomalies in machine operation; please
find below wording which could appear on display, the eventual anomaly or cause and corresponding remedy.
OPE n +
acustin signal
T 1 +
acustic signal
T 2 +
acustic signal
T 3 +
acustic signal
H20 +
acustic signal
AL4 +
acustic signal
AL3 +
acustic signal
AL2 +
acustic signal
First and tenth LED
blinking
CAUSE
Lid open
Intervention of the thermic of the compressor engine.
The resetting of the thermic is automatic and takes place when the temperatu-
re of the engine windings has gone below the safety levels.
To continue the production, the chosen cycle needs to be reset.
Intervention of the thermic of the mixer engine.
The resetting of the thermic is automatic and takes place when the temperatu-
re of the engine windings has gone below the safety levels.
To continue the production, the shosen cycle needs to be reset.
Intervention of the thermic of the emulsifier engine.
The resetting of the thermic is automatic and takes place when the temperatu-
re of the engine windings has gone below the safety levels.
To continue the production, the chosen cycle needs to be reset.
Intervention of the pressure switch of the cooling circuit.
Lack of water delivery from the water web.
Check whether the water tap is open.
Check the water delivery from the water web.
Overheating of the mix.
The temperature probe has measured 120° C.
Stop the machine and call the technical service.
Temperature under the levels.
The temperature probe has measured -15°C.
Stop the machine and call the technical service.
Anomaly of the temperature probe.
Short circuit or interruption of the probe connection.
Interruption of the electric energy.
See the A26 paragraph - Black out.
In all cases, it is advisable to call technician, indicating type of wording, so that same may efficiently
intervene.
WORDING ON
DISPLAY