7. Connect the power cord and switch the power
ON
.
8. Verify the Drive Belt alignment and tension to specification. see
and Alignment Adjustment" on page 58
.
9. Reinstall the hood cover, see
"Hood Cover Replacement" on page 88
10. Do the Operation Verification tests (see
"Operation Verification" on page 24
) and
return to service.
Common Frame Drive Motor Replacement
Review entire procedure before starting.
Removal
1. Switch the power
OFF
and unplug the power cord.
2. Remove the hood cover, see
"Hood Cover Replacement" on page 88
.
3. Disconnect the Motor Controller "MTH" and "MOTOR" electrical connections:
a. Remove the two left side MC fasteners and loosen the two right side fasteners.
Then slide the MC base to the left and remove the MC from the fasteners, see
"Motor Controller (MC) Replacement" on page 123
b. Lift the front of the MC just enough to access and disconnect the MC "MTH" I/O
connector. Then lift the rear of the MC just enough to access and disconnect
the MC "MOTOR" I/O connector.
c. Remove the MOTOR interface cable from the three frame routing cable
clamps.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 160
6 Replacement Procedures
Drive Motor Replacement