P62, P80, and P82 consoles: Club Settings
(5651565) >
Maintenance
menu >
Belt Rating
2. Do the troubleshooting instruction for the current Belt Rating number:
Belt Rating 2 thru 10
:
1. Clean the belt and deck, see
"Running Belt and Deck Cleaning Procedure" on
2. On P10, P30, P30i and P31 consoles. Reset the Belt rating to 10 by holding down the
QUICKSTART
key while viewing the Information Display > Belt Rating parameter.
3. On P62, P80, and P82 consoles: Reset the Next Maintenance Due (
Club Settings
(5651565) > Maintenance > Recommended Action > Next Maintenance Due
)
and Operating Condition (
Club Settings (5651565) > Maintenance > Recom-
mended Action > Operating Condition
).
4. Run a manual workout between 6 and 11 mph and verify that the Belt Rating is a
higher number and that the ASL has returned to Solid Blue.
5. If the ASL light has returned to the Pulsing Blue state, replace the belt and deck sur-
face (either flip the deck or replace deck if both surfaces are used.).
Belt Ratings 1 and 0
:
1. Replace the belt and deck surface (either flip the deck or replace deck if both surfaces
are used.).
2. On P10, P30, P30i and P31 consoles. Reset the Belt rating to 10 by holding down the
QUICKSTART key while viewing the Belt Rating parameter (
Information Display
>
Belt Rating
).
3. On P62, P80, and P82 consoles: Reset the Next Maintenance Due (
Club Settings
(5651565) > Maintenance > Recommended Action > Next Maintenance Due
)
and Operating Condition (
Club Settings (5651565) > Maintenance > Recom-
mended Action > Operating Condition
).
4. Run a manual workout between 6 and 11 mph and verify that the Belt Rating is a
higher number and that the ASL state has returned and remains Solid Blue.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 275
7 Troubleshooting
System Troubleshooting Procedures