The Incline Test diagnostic test will allow the incline to be changed without the running belt
movement requirement. The Incline Test also allows lift incline control during an out-of-
range lift position fault. This allows recovery from an out-of-range fault condition.
Lift motor schematic
"Lift Platform Replacement" on page 212
Procedure
1. Switch the input power OFF. Visually inspect the lift motor cable wires for damage
(torn insulation, bare wires, shorted/open wires, etc.) and MC module
I/O
1
connectors
for any damaged pins, shorted pins, or improperly crimped connections.
2. Switch the power ON. Verify the lift system operation, If there are still faults with the lift
system, continue procedure.
3. Review the Error Log and record any current and past lift system error codes. Then
use the
Error Code Troubleshooting Guide
(see
Error Code Troubleshooting Guide
)
to isolate and resolve the fault condition.
a. Along with the Error Code and Troubleshooting Guide, review the following sup-
plemental information to help troubleshoot and resolve any failures.
Additional Information
Use the following additional troubleshooting information along with the
Error Code and
Troubleshooting Guide
to help troubleshoot and resolve any failures
Error Code 40 "NO Lift Motion Detected"
Use the
Error Code Troubleshooting Guide
(see
Error Code Troubleshooting Guide
) for
troubleshooting and repair information.
1
Input and Output Interface.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 269
7 Troubleshooting
System Troubleshooting Procedures