2. Reconnect the motor static bleed resistor ground wire and secure using the 5/16 " hex
head fastener. Fully tighten the fastener to ensure good electrical contact with the
frame weldment.
WARNING
: Static electric shock hazard. Make sure the motor static bleed resistor
ground wire is securely connected to the frame. When the ground wire is not con-
nected, touching the motor housing could cause static charge electrical shock
and personal injury.
3. Reconnect the Motor Controller "MTH" and "MOTOR" cable connectors , see
Controller (MC) Replacement" on page 123
. Make sure the cable connectors have
the correct orientation and alignment before inserting into the MC
I/O
1
connector.
1
Input and Output Interface.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 158
6 Replacement Procedures
Drive Motor Replacement