Disabling the ASL Maintenance Reminder
When set to ON, the ASL maintenance reminder - pulsing blue light state is triggered ON
when the maintenance counter counts down to zero miles (or zero hours). When set to OFF,
the ASL Maintenance Reminder counter is ignored and the ASL state is not changed to
pulsing blue.
l
The "OFF" setting effectively disables the ASL "blue pulsing" state without affecting
the yellow or pulsing yellow fault states.
l
When set to OFF, the Maintenance Reminder counter continues counting down the
miles (or hours) remaining which can be viewed in the service access menu, see
"Viewing the current ASL state" below
.
l
Error code events will still affect the ASL state condition even when the Maintenance
Reminder is set to OFF.
P10, P30, P30i and P31 consoles:
Access
Club Settings (5651565)
>
MAINT CONFIG
> select
ON
or
OFF
.
P62, P80, and P82 consoles:
Access
Club Settings
(5651565) >
Maintenance
menu >
Maintenance Reminder
>
select
ON
or
OFF.
Viewing the current ASL state
The current ASL state (solid blue, pulsing blue, solid yellow; or pulsing yellow) can be
viewed using the service menu
ACTIVE STATUS LIGHT
parameter.
P10, P30, P30i and P31 consoles:
Access
Hardware Validation (51765761)
>
ACTIVE STATUS LIGHT
> current ASL state.
P62, P80, and P82 consoles:
Access
Club Settings
(5651565) >
Maintenance
menu >
ACTIVE STATUS LIGHT
> cur-
rent ASL state.
Viewing the ASL maintenance counter remaining miles (or hours)
P10, P30, P30i and P31 consoles:
Access
Information Display (65)
>
MAINT COUNTER
: remaining miles (or hours) to zero.
P62, P80, and P82 consoles:
Access
Service Software
(51765761) >
Maintenance
menu >
Next Maintenance Due
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 239
7 Troubleshooting
Active Status Light (ASL)