![Powtran ADSD-S-S Series Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/powtran/adsd-s-s-series/adsd-s-s-series_manual_1592614018.webp)
Chapter 4 Panel and keyboard display and operation
ADSD-S-S
35
Parameters to write
Means the parameters of the table will be written into EEPROM. Users modified the
parameters, only change the parameter values of the table, when the next time turned on that will
return to the original value. If want to permanent change parameter value, you need to perform
operation parameters, the parameter of table parameters must been written into EEPROM, the
electricity use after modification of the parameters.
Parameters to read
Means the parameters of the EEPROM will be read into the parameter table .This process
automatic to execute once when the electricity starting and the parameter table parameter value is
as same as EEPROM .But if the user change the parameter ,the same change of the parameter table
parameter value, If the modified numerical don't satisfied or the parameter was adjustable disorderly,
make to execution parameters read operation, will read the data of EEPROM again to the
parameter table, the parameters restore original value on electricity.
Restore default value
Means that will read all the default value of the parameters (the factory value) into parameter
table
,
and writes into EEPROM, the next time the electricity will use the default parameters, when
the user will parameters adjustment disorderly and unable to work, using this operation, would make
all the parameters back into a state of the factory. Because of the different type and electric machine
drive the corresponding parameter default values are different, in the use of restore default
parameters. Must ensure that drive code (parameter L001) and motor code (parameter L002) is right.
Chapter 4 Panel and keyboard display and operation
ADSD-S-S
36
4-6 Auxiliary function
In the main menu choice under the auxiliary function “P-”, press
key into the auxiliary
function method. Press
、
key to select the operation mode. After selected operating,
press
key to enter corresponding function then press
key to return to the operation mode
choosing state.
Special
parameters
Jog mode
Keyboard
speed
Analogue
speed
Corresponding
function operate
4-6-1 Special function
Manufacturers use
4-6-2 JOG function
Selecting the JOG operation "P-JOG", press
key enter the JOG operation mode. JOG move
prompt is“ ”, numerical unit is r/min, buttons provide speed instructions. Press
key to hold,
motor is positive turning according to JOG speed, loosen the buttons, the motor stops and keeps on
zero speed. Press
key to hold on, motor is negative turning according to JOG speed, loosen the
buttons, the motor stop, and keep the zero speed. JOG speed is set by L076 parameter
.
4-6-3 Keyboard speed
Selecting keyboard to tune speed “P-Sr”, press
key enter keyboard speed mode. The
keyboard speed prompt is“
”,numerical unit is r/min, buttons provide press instructions. Change
the
speed command by pressing
、
key, motor according to given speed to positive
operation. Positive means forward
(
CCW
)
,negative means reversal (CW),0.1r/min is the minimum
given speed.
4-6-4 Analogue adjustable zero
This device has no the function.