Chapter 4 Panel and keyboard display and operation
ADSD-S-S
31
project what they need, then press
key into the detailed show state.
Motor speed
(r/min)
Original position
pnstructions(Input Pulse)
Position instructions
(Pulse)
Current position
(Pulse)
Positional deviation
(Pulse)
Motor torque(%)
Peak torque(%)
Motor current(A)
Peak current(A)
Position instruction
phase frequency(Hz)
Speed instruction(r/min)
Torque instruction(%)
Input interface DI state
Output interface DO state
Encoder input signal
Rotor position absolutely
(phase)
Cumulative load rate
(%)
Regenerative braking
load rate(%)
Control modle
Alarm code
Retain
1000r/min
[Note1
][
Note2
]
50%
80%[Note4]
2.8A[Note3]
18.8KHz[Note5]
-85r/min
-20%
[Note6]
[Note7]
[Note8]
2480phase[Note9]
40%
30%
[Note10]
No alarm[Note11]
Retain
[Note1]
5.6A[Note4]
[Note1]
[Note1]
1. 32 bit binary numerical display.[Note1]
32 bit binary numerical range form
-2147483648
to 2147483647, use the combination of low and
high to display, through the menu to select low and high, by using figure formula to synthetic
formula full value.
Chapter 4 Panel and keyboard display and operation
ADSD-S-S
32
2. Pulse unit[Note 2]
The original position of the input pulse is refers to the instructions of the number of pulses, without
electronic gear change. Other project pulse unit is encoder pulse unit. To use 2500 line encoder for example:
Encoder pulse unit=Encoder resolution
=4*Encoder line number
=4*2500
(
pulse/rev
)
=10000
(
pulse/rev
)
3. Motor current [Note3]
Motor phase current effective value
.
4. Peak torque and current [Note4]
In the past 10 seconds, the largest motor torque and the maximum current effective value.
5. Position instructions pulse frequency [Note5]
Input the pulse frequency that was not throng the electronic gear actual frequency amplifier,
which positive direction shows positive number, negative direction shows negative number.
6.Input terminals DI [Note6].
Digital tube lines said a state, up the vertical bar stroke means on, or means off.
7. Output terminals DO [Note7].
Digital tube lines said a state, up the vertical bar stroke means on, or means off.