background image

Oct-18-700

 

Operation

 

Page 9 of 34

 

  All platform occupant(s) must always wear a certified CSA or OSHA approved full 

body harness attached and secured to the anchor provided at the upper controls’ 
station before entering the platform. 

  All platform occupants must always wear appropriate personal protective devices at 

all times (i.e. hard hats, safety shoes or boots; safety glasses, work gloves). 

  Never try to climb in or enter the platform, if the platform is not down to the ground. 

  Never place any item in the platform for the purpose of increasing work height (i.e. 

planks, ladders, step stools). 

  Never wear climbers inside the platform. 

  Before entering the platform, visually inspect the unit and test operate it at the 

beginning of each day by using the lower controls. 

 

During operation 

 

  Always maintain safe clearance from obstacles, electrical power lines and apparatus. 

The operator must allow for platform sway, rock or sag. 

  Always maintain a safe distance from overhead obstacles (including overhead 

electrical power lines). 

  Always maintain a clear view of the path of travel when operating from the platform. 

  Do not exceed the platform capacity that is stated on the serial number placard. 

  Understand the stability characteristics of this unit before using it. 

  All platform occupant(s) of this aerial device must always wear a certified CSA or 

OSHA approved full body harness attached to a lanyard while operating the unit from 
the platform.  The lanyard must be secured to the lanyard anchor (D-ring) at the boom 
tip. 

  All platform occupants must always wear appropriate personal protective devices at 

all times (i.e. hard hats, safety shoes or boots; safety glasses, work gloves). 

  Always stand firmly and keep both feet on the floor of the platform. 

  Never sit, stand, or climb on the edge of the platform. 

  Never place any item or equipment in the platform for the purpose of increasing work 

height (planks, ladders, step stools). 

  Never try to climb down from the platform, if the platform is not in the stowed position 

or down to the ground. 

  Make sure the platform floor is clear of debris, tools and other equipment that could 

make the operator unstable and prevent from having both feet on the floor during the 
operation. 

  Never belt off or tie off to an adjacent pole, structure or other equipment. 

  Operate the controls smoothly, avoiding rapid reversals. 

  Use care when getting on and off the unit and/or when entering and exiting the 

platform to avoid slipping or falling. Always maintain three points contact. 

 

 

Содержание Line Runner 700-40

Страница 1: ...ine Runner 700 40 Posi Plus Technologies Inc Copyright 2018 COPYRIGHT WARNING ANY REPRODUCTION OR DISTRIBUTION OF THIS WORK IN WHOLE OR IN PART BY ANY MEANS WHATSOEVER IS STRICTLY PROHIBITED WITHOUT T...

Страница 2: ...preoperational checks 15 Preparing for operation 18 Operating instructions 18 Section 5 Controls In cab controls 19 Intercom systems 19 Lower controls 21 Upper controls 22 Section 6 Operation Booms 2...

Страница 3: ...on could adversely affect the safe operation of this unit resulting in property damage and or personal injury Danger Electrocution Hazard This unit is a non insulating aerial device Maintain safe clea...

Страница 4: ...orm joystick will be dependent on the maximum flow available The standard flow available for this model is approximately 8 GPM at 1000 engine RPM This unit has been designed to be operated as a mobile...

Страница 5: ...Oct 18 700 Operation Page 5 of 34 Components identification TURRET PEDESTAL LOWER BOOM PLATFORM INTERCOM LOWER CONTROLS TELESCOPIC BOOM STABILIZER BAR IF APPLICABLE STABILIZER BAR IF APPLICABLE...

Страница 6: ...Oct 18 700 Operation Page 6 of 34...

Страница 7: ...the preventive instructions are not followed The following paragraphs from ANSI Z535 4 explain each term Danger Indicates an imminently hazardous situation which if not voided will result in death or...

Страница 8: ...ersonal injury and or property damage The operator bears ultimate responsibility for following all regulations and safety rules of their employer and or any state or federal law Never operate the aeri...

Страница 9: ...is stated on the serial number placard Understand the stability characteristics of this unit before using it All platform occupant s of this aerial device must always wear a certified CSA or OSHA appr...

Страница 10: ...rator is inside the platform It should only be operated on firm surfaces up to 5 degrees of inclination For a maximum stability the truck chassis must be on a level and firm surface only Danger Do not...

Страница 11: ...nd a drawing showing their location for this particular unit A copy of each decal follows the listing If for any reason any of the accident prevention signs are lost or become illegible replacements c...

Страница 12: ...Oct 18 700 Operation Page 12 of 34...

Страница 13: ...ation Consult the Stability Test report and the Parts Manuals for the applicable stabilizer options on this unit Stability or resistance to tipping is determined by the size and weight of the chassis...

Страница 14: ...ive 5 degrees For maximum stability the truck chassis must be on a level and firm surface It is impossible to foresee all possible situations and combinations for set up of the unit The operator bears...

Страница 15: ...s cracks wear or damage Special attention should be given to check fasteners of the following components Lower boom pivot pin Lower boom cylinder mounting pins Upper boom cylinder mounting pins Leveli...

Страница 16: ...m and it should not be possible to rotate the unit The machine must not be operated unless the trigger is working correctly Warning Platform occupant s must always wear a certified CSA or OSHA approve...

Страница 17: ...Oct 18 700 Operation Page 17 of 34 Figure 4 1...

Страница 18: ...ergized conductors Keep bystanders away from the lift and clear of working areas 4 Start the engine and turn ON the PTO PUMP switch of the cab control panel This switch starts the PTO PUMP hour counte...

Страница 19: ...lies DC power to the slave unit It has a push to talk switch that allows the driver to talk to the operator It is normally in the listen mode unless the switch is activated Volume of both speakers is...

Страница 20: ...o talk switch that allows the driver to talk to the operator It is normally in the listen mode unless the switch is activated Volume of both speakers is controlled from the master unit in the cab The...

Страница 21: ...sts of five 5 toggle switches that operate the following functions 2 Lower boom up down 3 Rotation CCW CW 4 Upper boom extend retract 5 Platform tilt 6 A three positions toggle switch Emergency pump O...

Страница 22: ...functions activated simultaneously Moreover the flow will divert to the maximum flow of the less demanding easiest to operate function first If there is still some flow available then the next less d...

Страница 23: ...l indicates the functions operated from the joystick The trigger must be depressed before to operate the boom functions The functions position of the unit may be different from the decal shown here ch...

Страница 24: ...ated through 370 degrees after the boom has been elevated to clear any obstacles The standard boom rotation movement stops approximately at 11 o clock on the roadside A planetary gearbox is used to dr...

Страница 25: ...ting the unit from the platform The lanyard must be secured to the lanyard anchor D ring near or on the platform All platform occupants must always wear appropriate personal protective devices at all...

Страница 26: ...le at all times In addition to keeping the platform level the system is capable of stowing the platform horizontal for road travel When the platform is unstowed and moved to the work position it can b...

Страница 27: ...ght of the material before moving it Use the placards provided on the machine and in the Operator s Manual to determine the available rated lifting capacities of the lower boom lifting eye Do not exce...

Страница 28: ...ling eye without having the booms directly over the load If an excessive side load is developed on the booms the gearbox and rotation motor will back drive and the rotation brake will slip This allows...

Страница 29: ...ts operation of the aerial device from the lower hydraulic controls Emergency lowering DC pump If a situation arises that the machine cannot be operated due to a loss of hydraulic power such as engine...

Страница 30: ...is held in this position When the switch is not held in this position it automatically comes back to the neutral position to stop the DC pump The DC pump can be heard while it is operating Since the...

Страница 31: ...sing the Emergency lowering DC pump system Low fluid level in reservoir Check fluid level Add fluid to the Full mark Use correct type of fluid Oil reservoir gate valves closed Check gate valves and op...

Страница 32: ...ed by following the guidelines recommended in the Maintenance Manual for top performance from the hydraulic system When cleaning the unit care should be taken not to spray water under pressure directl...

Страница 33: ...ound booms in the boom rest the oil level should be between the Add and the Full marks on the filler cap dipstick or applicable sight gauge If oil must be added oil of the proper type as described in...

Страница 34: ...increase the life of the machine and help to avoid future maintenance problems Any squeaky or jerky action of the moving parts on the aerial device is an indication that lubrication is needed immedia...

Отзывы: