Oct-18-700
Operation
Page 23 of 34
Boom upper controls
The one-hand joystick control mounted on the side of the platform operates the aerial
device movement.
Emergency stop
Whenever required the emergency stop can be used to stop all
boom functions. To activate, push down the red push button
that is installed on top of the upper controls’ enclosure. Even if
the single handle controller is activated in any position, the
emergency stop can always be applied.
The emergency stop deactivates the electronic controls. Operation can still be done from
the pedestal control if “Lower controls’’ is selected at lower portable control.
Joystick
When a function is operated, the function's speed is
proportional to the distance the single handle upper
control is shifted.
A decal indicates the functions operated from the joystick.
The trigger must be depressed before to operate the boom
functions.
The functions position of the unit may be different from the
decal shown here, check the part manual for the specific
decal.
Caution
The interlock button should be fully depressed before the controller handle is
moved in any direction. Moving the handle first, before depressing the button, may
produce sudden and rough movement of the platform. Releasing the interlock
button before centering the control handle may produce sudden and abrupt
stopping of movement.
Emergency pump
A spring return toggle switch or a push button allows operating the
boom functions with the emergency pump. Hold the control while
operating with the joystick.
Platform tilt
A spring return toggle switch allows tilting the platform to the “Tilt” position
or to the “Working” position. This function allows also setting the platform
level for a comfortable working position.