From the upper controls, to start the emergency DC pump, press and hold the "Emergency
pump" switch while operating with the control joystick.
From the lower controls, to start the emergency DC pump, hold the switch in the
"emergency pump" position while operating the toggle switches. The pump will continue
to operate as long as the switch is held in this position. When the switch is not held in this
position, it automatically comes back to the neutral position to stop the DC pump.
The DC pump can be heard while it is operating. Since the emergency lowering pump
has a smaller capacity than the main pump, the functions speeds will be reduced when
using the emergency pump.
Rotate or lower the unit enough to position the platform clear of the work area. Then lower
the unit to the ground, or to a position where the operator(s) may get out of the platform.
The unit may then be stowed using the lower controls.