Oct-18-700
Operation
Page 27 of 34
Lower boom lifting eye
This attachment adapts the lower boom for light-duty material
handling. The lifting eye provides a secure mounting for a
shackle at the end of the lower boom. The lifting eye is rated for
1000 pounds at any boom angle.
Warning
The lower boom lifting eye should only be used when the platform is not occupied.
Always keep the upper boom as near to the stowed position as possible. Be careful
of striking the vehicle or other obstacles with the platform.
Caution
Never lift an unknown load. Determine the weight of the material before moving it.
Use the placards provided on the machine and in the Operator's Manual to
determine the available rated lifting capacities of the lower boom lifting eye. Do not
exceed the rated lifting capacities of the lower boom lifting eye.
120 Volts AC power source (option)
Electric power is provided at the platform through an electric cable which is carried in the
chain link hose tracking system.
At the platform electrical outlet, a ground fault circuit-interrupter is provided protecting
personnel when a fault current to ground exceeds the predetermined setting.
The ground fault circuit-interrupter should be tested frequently. Push the “Test” red button,
the circuit must become unloaded. Push the “Reset” button to reactivate the outlet.