background image

Oct-18-700

 

Operation

 

Page 15 of 34

 

Daily preoperational checks 

 
The aerial device should be inspected at the beginning of each work day, before going 
out on the job.  By spending a few moments every day inspecting the unit, potential service 
and safety problems may be detected.  

The following inspections and tests shall be 

performed by the operator immediately prior to first use at the beginning of each 
shift

 
The following items should be checked during the daily pre-operation inspection. 
 
1.  Check the oil level of the hydraulic reservoir.  The oil level must be between the Add 

and Full marks on the sight gauge with the truck on level ground, booms in the rest 
position.  If necessary, add oil of the proper type as described in the Maintenance 
Manual.  The need to add oil on a regular basis indicates a leak in the hydraulic system 
which should be corrected. 

 

2.  Conduct a visual inspection of the unit. Inspect pins, fasteners, structures and welds 

for looseness, cracks, wear or damage. Special attention should be given to check 
fasteners of the following components: 

 

 

Lower boom pivot pin. 

 

Lower boom cylinder mounting pins. 

 

Upper boom cylinder mounting pins. 

 

Leveling cylinders mounting pins. 

 

Platform mounting shafts. 

 

Platform mounting fasteners. 

 

3.  Check the electrical and hydraulic system, wire routing, hydraulic cylinders, hoses and 

tubes for leakage or damage.  Any loose or damaged component, fasteners, hose, 
tube, pin or weld must be repaired or replaced before operating the unit. 

 

Warning

 

Do not use hands or other body parts to check hydraulic lines and fittings for leaks. 
Death or serious injury can result from hydraulic oil being injected into the flesh. 

 
4.  Visual and audible safety devices should be checked for proper operation.  Any 

malfunction, missing or illegible markings or placards should be corrected before 
operating the unit. 

 

5.  Check the tires for proper inflation, no damages. 

 

6.  Check the stabilizer bar(s), look for deformation or damage, visible defects, rubbers 

condition. 

 

7.  Apply the parking brake, start the engine and engage the PTO. 

 

8.  Check the voice communication system, upper speaker and in cab intercom. 

 

Содержание Line Runner 700-40

Страница 1: ...ine Runner 700 40 Posi Plus Technologies Inc Copyright 2018 COPYRIGHT WARNING ANY REPRODUCTION OR DISTRIBUTION OF THIS WORK IN WHOLE OR IN PART BY ANY MEANS WHATSOEVER IS STRICTLY PROHIBITED WITHOUT T...

Страница 2: ...preoperational checks 15 Preparing for operation 18 Operating instructions 18 Section 5 Controls In cab controls 19 Intercom systems 19 Lower controls 21 Upper controls 22 Section 6 Operation Booms 2...

Страница 3: ...on could adversely affect the safe operation of this unit resulting in property damage and or personal injury Danger Electrocution Hazard This unit is a non insulating aerial device Maintain safe clea...

Страница 4: ...orm joystick will be dependent on the maximum flow available The standard flow available for this model is approximately 8 GPM at 1000 engine RPM This unit has been designed to be operated as a mobile...

Страница 5: ...Oct 18 700 Operation Page 5 of 34 Components identification TURRET PEDESTAL LOWER BOOM PLATFORM INTERCOM LOWER CONTROLS TELESCOPIC BOOM STABILIZER BAR IF APPLICABLE STABILIZER BAR IF APPLICABLE...

Страница 6: ...Oct 18 700 Operation Page 6 of 34...

Страница 7: ...the preventive instructions are not followed The following paragraphs from ANSI Z535 4 explain each term Danger Indicates an imminently hazardous situation which if not voided will result in death or...

Страница 8: ...ersonal injury and or property damage The operator bears ultimate responsibility for following all regulations and safety rules of their employer and or any state or federal law Never operate the aeri...

Страница 9: ...is stated on the serial number placard Understand the stability characteristics of this unit before using it All platform occupant s of this aerial device must always wear a certified CSA or OSHA appr...

Страница 10: ...rator is inside the platform It should only be operated on firm surfaces up to 5 degrees of inclination For a maximum stability the truck chassis must be on a level and firm surface only Danger Do not...

Страница 11: ...nd a drawing showing their location for this particular unit A copy of each decal follows the listing If for any reason any of the accident prevention signs are lost or become illegible replacements c...

Страница 12: ...Oct 18 700 Operation Page 12 of 34...

Страница 13: ...ation Consult the Stability Test report and the Parts Manuals for the applicable stabilizer options on this unit Stability or resistance to tipping is determined by the size and weight of the chassis...

Страница 14: ...ive 5 degrees For maximum stability the truck chassis must be on a level and firm surface It is impossible to foresee all possible situations and combinations for set up of the unit The operator bears...

Страница 15: ...s cracks wear or damage Special attention should be given to check fasteners of the following components Lower boom pivot pin Lower boom cylinder mounting pins Upper boom cylinder mounting pins Leveli...

Страница 16: ...m and it should not be possible to rotate the unit The machine must not be operated unless the trigger is working correctly Warning Platform occupant s must always wear a certified CSA or OSHA approve...

Страница 17: ...Oct 18 700 Operation Page 17 of 34 Figure 4 1...

Страница 18: ...ergized conductors Keep bystanders away from the lift and clear of working areas 4 Start the engine and turn ON the PTO PUMP switch of the cab control panel This switch starts the PTO PUMP hour counte...

Страница 19: ...lies DC power to the slave unit It has a push to talk switch that allows the driver to talk to the operator It is normally in the listen mode unless the switch is activated Volume of both speakers is...

Страница 20: ...o talk switch that allows the driver to talk to the operator It is normally in the listen mode unless the switch is activated Volume of both speakers is controlled from the master unit in the cab The...

Страница 21: ...sts of five 5 toggle switches that operate the following functions 2 Lower boom up down 3 Rotation CCW CW 4 Upper boom extend retract 5 Platform tilt 6 A three positions toggle switch Emergency pump O...

Страница 22: ...functions activated simultaneously Moreover the flow will divert to the maximum flow of the less demanding easiest to operate function first If there is still some flow available then the next less d...

Страница 23: ...l indicates the functions operated from the joystick The trigger must be depressed before to operate the boom functions The functions position of the unit may be different from the decal shown here ch...

Страница 24: ...ated through 370 degrees after the boom has been elevated to clear any obstacles The standard boom rotation movement stops approximately at 11 o clock on the roadside A planetary gearbox is used to dr...

Страница 25: ...ting the unit from the platform The lanyard must be secured to the lanyard anchor D ring near or on the platform All platform occupants must always wear appropriate personal protective devices at all...

Страница 26: ...le at all times In addition to keeping the platform level the system is capable of stowing the platform horizontal for road travel When the platform is unstowed and moved to the work position it can b...

Страница 27: ...ght of the material before moving it Use the placards provided on the machine and in the Operator s Manual to determine the available rated lifting capacities of the lower boom lifting eye Do not exce...

Страница 28: ...ling eye without having the booms directly over the load If an excessive side load is developed on the booms the gearbox and rotation motor will back drive and the rotation brake will slip This allows...

Страница 29: ...ts operation of the aerial device from the lower hydraulic controls Emergency lowering DC pump If a situation arises that the machine cannot be operated due to a loss of hydraulic power such as engine...

Страница 30: ...is held in this position When the switch is not held in this position it automatically comes back to the neutral position to stop the DC pump The DC pump can be heard while it is operating Since the...

Страница 31: ...sing the Emergency lowering DC pump system Low fluid level in reservoir Check fluid level Add fluid to the Full mark Use correct type of fluid Oil reservoir gate valves closed Check gate valves and op...

Страница 32: ...ed by following the guidelines recommended in the Maintenance Manual for top performance from the hydraulic system When cleaning the unit care should be taken not to spray water under pressure directl...

Страница 33: ...ound booms in the boom rest the oil level should be between the Add and the Full marks on the filler cap dipstick or applicable sight gauge If oil must be added oil of the proper type as described in...

Страница 34: ...increase the life of the machine and help to avoid future maintenance problems Any squeaky or jerky action of the moving parts on the aerial device is an indication that lubrication is needed immedia...

Отзывы: