12 Saved HACCP data
HACCP logs can be saved to a USB memory stick by selecting
button
Log file Management
in control panel.
From the opening menu you select the desired function
according to figure 20.
13 Alarms
For HACCP the equipment has the following alarms:
ROOM HIGH TEMP
Internal cabinet temperature too high
MAX CYCLE TIME
Function time limit exceeded
POWER FAIL
Function interrupted due to power failure
Error messages related to the equipment function can be
acknowledged by
button. It does not turn off the alarm
but mutes the buzzer. Alarm ceases when the error is gone.
Error messages can be viewed with button
.
Fig. 19. Service control panel
Log file Management
HACCP log
Fig. 20. HACCP logs
Export HAACP.txt log file
Save HACCP report
Export Alarm.txt log file
Save HACCP deviation report
Export both log files
Save both
Fig. 21. Equipment error messages
Alarm acknowledgement
Definition of error messages
RPF
Internal temperature probe faulty
EPF
Evaporator probe faulty
CPF
Condenser probe faulty
NPF
Product probe faulty
RLT
Indoor temperature too cold
EXT
External input alarm
DOOR
Door open
CHT
Clean condenser
CLT
Ambient temperature too cold