113
Mounting standard metal fixtures (PDM-4001)
3. It is possible to stack up to four units using the multiple installation fixtures. For four-unit stacking, it is necessary to
take measures against falling by either securing the cradle to the floor with anchors, securing the upper portion by
suspending from the ceiling or bolting to the ceiling or securing the back side to the wall with bolts, etc.
Upper portion
To prevent falling, use these holes to secure
the upper portion by suspending from the
ceiling or the wall.
Back side
To prevent falling, use these holes
to secure to the wall, etc.
Secure the cradle using anchors. Moreover, for the actual
examples of installation works in which suspension bolts
and anchors were used, see the attached manual
(ZMZ014) for the installation and implementation of the
exclusive fixture (TVK series) for the system monitor.
Cradle
floor
• Make sure to confirm the strength after installing
anchors. They may come off due to defective
installation or concrete work.
• For detailed information on the size and strength of
anchors, see the product catalogs of anchors, etc.
• We are not responsible for any accidents or damages
caused due to insufficient strength of anchors or
defective anchor installation work.
Caution
Содержание PDA-4002
Страница 5: ...5 Features ...
Страница 21: ...21 Installation procedure ...
Страница 57: ...57 Special installation Installation under the floor ...
Страница 69: ...69 Mounting standard metal fixtures PDK 4001 ...
Страница 75: ...75 Mounting standard metal fixtures PDK 4002 ...
Страница 81: ...81 Mounting standard metal fixtures PDK 4004 ...
Страница 131: ...131 Mounting standard metal fixtures Precautions for installing the optional speaker ...
Страница 135: ...135 Before making adjustments ...