5 0
Special installation (Ceiling embedding)
3.4.9 Ceiling embedding
This display is designed to accommodate embedding in a ceiling. Note that the allowable range of outside-air temperature
depends on the installation conditions. Please observe the following requirements:
1
Use a mounting fixture with a shape that does not block ventilation holes on the back or disturb ventilation in
any way, and secure the display at four or more points. Moreover, when installing this display, ensure that the
deformation such as twisting and bending of this display can be kept within 1 mm. Otherwise, it is likely that
PDP panel will cause cracks.
2
Do not use cable clamps for this installation method. Cable clamps can interfere with proper ventilation and
result in device failure.
3
Installation conditions and ambient operating temperatures:
(1) When the space above the ceiling is not enclosed:
A
A
Intake (holes other than
that of fan)
Exhaust
A
100 mm
100 mm
PC-9800 (56.4Hz)
PC-9800 (70.1Hz)
Clearance A to the wall
VIDEO
Machintosh (66.7Hz)
VGA (60HZ)
VGA (72.8Hz, 75Hz)
A
≤
150 mm
0~40
°
C
0~40
°
C
0~35
°
C
Working temperature requirements
100 mm
100 mm
* The same conditions apply to the working temperature requirements for a speaker system (PDP-S03-LR).
Содержание PDA-4002
Страница 5: ...5 Features ...
Страница 21: ...21 Installation procedure ...
Страница 57: ...57 Special installation Installation under the floor ...
Страница 69: ...69 Mounting standard metal fixtures PDK 4001 ...
Страница 75: ...75 Mounting standard metal fixtures PDK 4002 ...
Страница 81: ...81 Mounting standard metal fixtures PDK 4004 ...
Страница 131: ...131 Mounting standard metal fixtures Precautions for installing the optional speaker ...
Страница 135: ...135 Before making adjustments ...