2 6
Special installations (Wall hanging)
3.4.2 Wall hanging
This display may be wall-mounted. Since this form of mounting affects ventilation patterns inside, observe the following
requirements:
1
When mounting plate metal, avoid blocking any ventilation holes.
Use plate metal of the size indicated in the
following drawing.
2
Provide space for adequate ventilation between the wall and the display.
3
Use plate metal having sufficient strength (with a safety factor of approximately four), and attach at four points (4-
point mounting) as shown below. Since wall installations involve certain hazards, always follow double-safety
procedures.
4
The following table lists proper operating temperatures. Use the display within the listed range of outside air
temperature.
5
Keep deformation of the display to 1 mm, including twisting and bending.
Do not block this area at either the top or bottom.
40mm
Do not block this area at either the left or right.
40mm
A
75mm 75mm
Wall
694 mm (center indicated)
75mm 75mm
PC-9800 (56.4Hz)
PC-9800 (70.1Hz)
Clearance A to the wall
VIDEO
Machintosh (66.7Hz)
VGA (60Hz)
VGA (72.8Hz, 75Hz)
Less than 50 mm
0~35
°
C
0~35
°
C
Not usable
50 mm or more
0~40
°
C
0~40
°
C
0~35
°
C
50mm
50mm
* The same conditions apply to the working temperature requirements for a speaker system (PDP-S03-LR).
Содержание PDA-4002
Страница 5: ...5 Features ...
Страница 21: ...21 Installation procedure ...
Страница 57: ...57 Special installation Installation under the floor ...
Страница 69: ...69 Mounting standard metal fixtures PDK 4001 ...
Страница 75: ...75 Mounting standard metal fixtures PDK 4002 ...
Страница 81: ...81 Mounting standard metal fixtures PDK 4004 ...
Страница 131: ...131 Mounting standard metal fixtures Precautions for installing the optional speaker ...
Страница 135: ...135 Before making adjustments ...