GENERAL RULES
The stove/fireplace must have the necessary air available to ensure
proper combustion.
- Make sure that the room in which the stove/fireplace is to be installed
has an air intake of at least the size indicated in the paragraph
“
TECHNICAL DATA
”.
- The fresh air intake may be protected by an external grille provided it
does not reduce the minimum section of the recommended airflow
and is in a position whereby it cannot be obstructed.
The air necessary for the fire may be obtained in different ways:
-
Figure 12
through an external grille direct to the room of installation;
-
Figure 13
with ducting through pipes direct to the room of
installation, increasing the recommended minimum free cross
section by at least 15%;
-
Figure 14
through a communicating hole from an adjacent room to
the place of installation: this system may only be used if the air flows
freely from the outside through fixed apertures;
-
Figure 15
from an adjacent room to the place of installation, but only
if the air flows freely through apertures communicating with the
outside.
DT2030054-00
Fig. 12
DT2030194-00
Fig. 14
DT2030195-00
Fig. 15
DT2030193-00
Fig. 13
1.4 FRESH AIR INTAKE - Fig. 12 / 15