English
24
USE
STARTUP
Action
Function
Display
Hold the on/off key
down for several
seconds
A cycle starts with three phases which take
the stove into the normal operating mode:
• CONTROL (first 20 seconds)
Fault chech.
The lighter (glow plug) activates.
• START PHASE I
The extractor fan starts up.
The fuel-loading auger is activated and starts to
feed pellets into the grate.
• START PHASE II
If the lighter has triggered the combustion process, the
fuel-loading auger increases to allow a period of
stabilisation and correct combustion of the pellets in the
subsequent normal operating mode.
If during the startup phase the sensor on the flue gas
outlet shows a rise in temperature (sign that the
combustion process is underway), the stove is
considered to be lit and goes into the normal operating
mode.
If during the startup phase the sensor on the flue gas
outlet does NOT show a rise in temperature (sign that the
combustion process is not underway), the stove should
be considered off; a new ignition cycle will begin
automatically and the three preceding phases will be
repeated in succession.
MENU
SET
ESC
OPT
DT2040051-06
C O N T R O L
1 2 : 0 0
2 2
.
c
!
!
1
S T A R T
P H A S E
I
1 2 : 0 0
2 2
.
c
!
!
1
FAILED IGNITION
Action
Function
Display
A second failed ignition is indicated on the display.
In the STOVE STATUS function by the readout “NO
ACC” as well as the smoke sensor temperature,
see “PROGRAMMING” paragraph. In addition a
beep is emitted once every 5 seconds. This safety
device is activated if the pellets do not ignite, if the
pellet hopper is empty or if the temperature fails
to rise.
N O
L I T
!
!
1
DT2040056-04
S T A R T
P H A S E
II
1 2 : 0 0
2 2
.
c
!
!
1