English
21
INSTALLATION
• The redirection of heat to adjoining rooms is at the user’s
discretion.
• The Y-connector can be attached to either fan.
• You can choose to use only one of the fans’ outlets to heat
adjoing rooms, in which case it is more convenient to use the
right fan. Proceed as follows:
For convenience, the following assembly operations should
be carried out during the installation phase first on the left fan
(as viewed from the rear) and then on the right fan (fig 47).
1. Take off the stove’s back panel
2. Uncoil the flexible pipe from the fan’s outlet by unscrewing the
clip which holds it in place.
3. Cut around 5cm of flexible pipe (fig 48).
4. Fix the flexible pipe to the Y-connector using the clip provided
(fig 49).
5. Fix the Y-connector to the fan’s outlet using the screws
provided (fig 50). (for the left fan see fig 52)
6. Attach the second flexible pipe to the Y connector using the clip
provided (fig 51).
7. Repeat stages 2 - 6 for the right fan.
8. Take off the sub-section of the back panel (fig 54).
9. Replace the back panel.
10. Move the stove closer to the wall (fig 53) and, using the clips
provided, fix the two flexible pipes to the pipes in the wall (fig
55).
11. Place the stove in the desired location, respecting the minimum
safety distances (see section 1.8).
DT2030230-00
DT2030229-00
DT2030178-00
DT2030175-00
Fig. 47
Fig. 48
Fig. 49
Fig. 51
DT2030232-00
Fig. 50
DT2030181-00
DT2030233-00
Fig. 54
Fig. 55
DT2030180-00
DT2030231-00
Fig. 52
Fig. 52
Fig. 53
left fan
right fan
tightening screws
5.4 INSTALLING THE Y CONNECTOR (OPTIONAL) - Fig. 47 / 55
DT2010148-03