English
42
USE
FLUE GAS TEMPERATURE SENSOR
Sensor
Description
Display
Smoke sensor
Connected to the electronic board, it constantly
monitors the working temperature allowing the
stove to be used in all safety.
WHEN ACTIVATED
If the temperature exceeds the fixed safety limit
the board cuts off the power supply to the fuel-
loading auger thus depriving the grate of pellets
and starting the stove shutdown process.
- The readout
MASS TEMP
and the flue gas
temperature appear in the STOVE STATUS
mode.
- After approx. 60 seconds the alarm sounds (if
activated).
WHAT TO DO
- Shut down the stove by holding the ON/OFF key
down for several seconds.
- The alarm stops.
- Wait until you are sure that combustion of any
pellets remaining in the grate has stopped.
- Check for and remove whatever has triggered
the safety device.
- After having cleaned the grate restart the stove
by pressing the ON/OFF key.
Smoke sensor
Disconnected
WHEN ACTIVATED
If the sensor is momentarily or accidentally
removed from its normal position, or is not
connected properly to the electronic board, the
readout
NO CONN
and the flue gas temperature
will appear in the STOVE STATUS mode. After
approx. 60 seconds the alarm sounds (if
activated).
WHAT TO DO
- Shut down the stove by holding the ON/OFF key
down for several seconds.
- The alarm stops.
- Wait until you are sure that combustion of any
pellets remaining in the grate has stopped.
- Check for and remove whatever has triggered
the safety device.
- After having cleaned the grate, restart the stove
by pressing the ON/OFF key.
DT2040054-02
S A F E T Y
S T O V E
!
1
!
P R O B E
S M O K E
!
1
!
!
!