background image

           

 

 

Gas Heavy Duty Stock Pot Stove 

Operating Instructions 

 

 

 

 

 

 

 

 

Before you begin, please read these instructions carefully to 

use this product correctly, to make the product perform ideally, and 

to avoid hazards. 

 

Models: ATSP-18-1/ ATSP-18-2 

              ATSP-18-1L/ ATSP-18-2L 

Содержание ATSP-18-1

Страница 1: ...t Stove Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models ATSP 18 1 ATSP 18 2 ATSP 18 1L ATSP 18 2L ...

Страница 2: ...manual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation The appliance is designed for commercial purposes not for household use A statement instructing the purchaser to post in a prominent location instructions to be followed in the event the user smells gas...

Страница 3: ...3 2 Brief Introduction 3 3 Manufacturer s Authority and Responsibility 3 4 Parameter Specifications 4 5 Transport and Storage 6 6 Installation and Debugging 6 7 Safety Notices and Precautions 8 8 Operating Instructions 9 9 Cleaning and Maintenance 11 10 Troubleshooting 12 11 Spare Parts 14 12 Accessories List 18 ...

Страница 4: ... lack the necessary knowledge or experience unless with appropriate instructions and sufficient safety 2 Brief Instruction The product is a series of gas char broilers in our company production which is novel designed reasonable structured convenient operated durable used and convenient maintained It s equipped with a cast iron burner and a high efficiency stainless steel tubular burner and a pilo...

Страница 5: ...echnicians Use the spare parts or accessories provided by non manufacturers Accidents caused by force majeure Not strictly comply with related guide of this instruction by any reason 4 Parameter Specifications 4 1 Outline Dimensions in ATSP 18 1 ...

Страница 6: ... 5 ATSP 18 2 ...

Страница 7: ... 6 ATSP 18 1L ...

Страница 8: ...SP 18 2L 4 2 Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 4 Natural Gas W C and 10 L P Gas W C The external thread of product s intake tube is 3 4 inches ...

Страница 9: ...in open air for a long time and shall be placed in a well ventilated and non corrosive gases warehouse When equipment needs temporary storage rainproof measures should be taken 6 Installation and Debugging Any erroneous installation adjustment refit overhaul or maintenance may cause property damage or personal injury The work shall be performed by authorized and licensed technicians otherwise the ...

Страница 10: ...ventilation laws and codes are very different you should state and comply with all codes of the National Fire Protection Association Inc when it comes to requirements for installation of equipment Screw 4 adjustable stainless steel legs in the tapping hole with four corners of the charbroiled bottom ensure sufficient space for ventilation Adjustable stainless steel legs to make the equipment level...

Страница 11: ... to bargain Unplug pressure gauge after you accomplish pressure testing then install needle type pressure joint screw arbor Important must screw joint screw arbor to prevent gas escape 6 2 Debugging It s very important to debug the new stove Through the comprehensive system test of equipment we can ensure function and safety performance of products Discovering any potential problems before use suc...

Страница 12: ...ny spare parts without authorization Never change any other parts without authorization to this equipment otherwise may cause hazards and the manufacturer has the right not to provide warranty service Steel cutting producers used to manufacture with sharp edges The manufacturer has dealt with these sharp edges during production however we insist the operator take care when in contact with this pie...

Страница 13: ... fire burner is lighted by the pilot light The power of burner increases as revolving angel increases When knob reaches to burner is in the maximum power Fig 4 Fig 2 Fig 3 Fig 4 ATSP 18 1 L CONTROL PANEL ATSP 18 2 L CONTROL PANEL Burner outer ring Burner inner ring Front burner Front burner Back burner Back burner control knob control knob outer ring inner ring outer ring inner ring control knob c...

Страница 14: ... by protective lipids on the grates and other parts are heated it is normal and it will be eliminated after the power up to the maximum for burning an hour 8 5 Exchange main fire nozzle to switch gas source Remove control panel cooking grates the pilot light head and burner remove main fire nozzle with proper open spanner exchange nozzle of another gas source then screw it Fig 8 Reinstall burner t...

Страница 15: ...cleaning matters to wash even not use corrosive detergent Warning Before cleaning all control valves must be turned off Strictly follow the lighting instructions to work again after cleaning Warning Wait for the equipment to cool down after the unit has been turned off before you clean Cut off the gas source when not in use If the equipment is not used for a long time clean the surface by wiping i...

Страница 16: ...nd mild detergent daily Control panel Turn off valves when not in use Wipe panel and control valve knob with mild detergent daily Catch tray Pull out catch tray from front body until the equipment cools down Use a cloth with cleaning agent to wipe unit surface wipe up residue Reinstall after cleaning Warning if the catch tray is permitted to fill too high should be cleaned Per use ...

Страница 17: ...ard a sound of fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Not match nozzle aperture with gas resources 2 Adjust nozzle diameter 3 Flow of connection pipe is not enough 3 Increase pipe s allowable flow 4 Damper opening degree is too large 4 Adjust damper Yellow flame and black smoke 1 Use bottom gas 1 Change gas 2 Not match nozzle aperture with gas resources 2 Ad...

Страница 18: ...e warranty service Order replacement parts from authorized representatives and after sale service agency Provide the model number serial number and description when you order components Fig 10 8 10 11 13 12 15 14 18171612 19 20 21 22 20 21 13 23 24 17 16 4 29 30 20 21 32 31 33 25 26 27 28 1 2 3 4 5 6 7 9 ...

Страница 19: ...1L 6 ATSP 18 2L 3 21106001009 Control panel 1 453 155 ATSP 18 1 21106002011 ATSP 18 2 21106001009 ATSP 18 1L 21106002011 ATSP 18 2L 4 301081006 Galvanized American outside six corner with pad tapping 6 ST4 8 12 5 ATSP 18 1 8 ATSP 18 2 6 ATSP 18 1L 8 ATSP 18 2L 5 21106001010 Catch tray 1 460 365 13 ATSP 18 1 21106002012 990 365 13 ATSP 18 2 21106001010 460 365 13 ATSP 18 1L 21106002012 990 365 13 A...

Страница 20: ...her 2 Φ6 5 Φ18 ATSP 18 1 2 1L 2L 12 301030002 A18 stopcock 2 A18 318 ATSP 18 1 4 ATSP 18 2 2 ATSP 18 1L 4 ATSP 18 2L 13 301040012 A18 nozzle NG32 2 ATSP 18 1 301040013 A18 nozzle LP49 4 ATSP 18 2 301040012 A18 nozzle NG32 2 ATSP 18 1L 301040013 A18 nozzle LP49 4 ATSP 18 2L 14 301990006 Damper cover 2 ATSP 18 1 4 ATSP 18 2 2 ATSP 18 1L 4 ATSP 18 2L 15 301081011 Stainless steel cross screws 2 M5 10 ...

Страница 21: ...TSP 18 1 4 ATSP 18 2 2 ATSP 18 1L 4 ATSP 18 2L 21 211060001011 Pilot light head stator 2 ATSP 18 1 4 ATSP 18 2 2 ATSP 18 1L 4 ATSP 18 2L 22 21106002014 Front burner inner pilot intake tube 1 Φ4 7 0 6 ATSP 18 1 2 1L 2L 23 301080008 Brass lock nut 0 M18 ATSP 18 1 2 ATSP 18 2 0 ATSP 18 1L 2 ATSP 18 2L 24 301050014 Brass double male elbow 0 M16 turn to 3 8 27UNS ATSP 18 1 2 ATSP 18 2 0 ATSP 18 1L 2 AT...

Страница 22: ... 2 1 ATSP 18 1L 2 ATSP 18 2L 30 301010013 Boiler burner 1 Φ305 385 ATSP 18 1 2 ATSP 18 2 1 ATSP 18 1L 2 ATSP 18 2L 31 301070014 18 single head broiler in take tube 1 343 523 86 ATSP 18 1 301070015 18 double head broiler in take tube 343 1053 86 ATSP 18 2 301070014 18 single head broiler in take tube 343 523 86 ATSP 18 1L 301070015 18 double head broiler in take tube 343 1053 86 ATSP 18 2L 32 30108...

Страница 23: ...ure interface tightness 2 The pressure regulator s have connected the maximum load of natural gas cannot exceed 6 and of LP cannot exceed 12 3 Adjustment range of the pressure regulator s is 4 6 for natural gas and 7 10 for L P 4 Screw the hex nut Fig 11 before connect air intake ensure gas mark Fig 12 on the plastic core whether match with connected gas source if not then pull out the plastic cor...

Страница 24: ...ry maintenance can prolong life length of the products Contact the dealer for assistance In order to avoid confusion please follow the format in figure 10 and table 4 L I S E D T C US Intertek Conforms to ANSI STD Z83 11 2016 Certified to CSA STD 1 8 2016 LIS E D T Intertek 4003935 Conforms to NSF ANSI STD 4 S A N I TAT I ON ...