INSTALLER : THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

CERTIFIED IN CANADA TO CAN/CSA 22.2 #B40.0 - M87 &·R91 B140.1 & B140.3 CERTIFIED·IN THE UNITED STATES TO UL 896 -199

INSTALLATION AND OPERATION

INSTRUCTIONS FOR

OIL-FIRED CAST IRON STOVE

MODEL

OS10-3

WOLF STEEL LTD., RR#1, 24 NAPOLEON RD.,

BARRIE, ON., CANADA L4M 4Y8 (705)721-1212

Fax: (705)722-6031

Email :

[email protected]

Web:

WWW.NAPOLEONFIREPLACE.COM

Document n° 1092-1 EN ~ 04/02/2002

Installation and Service must be performed by a Qualified Installer, Service Agency or the Oil Supplier

Содержание OS10-3

Страница 1: ...O UL 896 199 INSTALLATION AND OPERATION INSTRUCTIONS FOR OIL FIRED CAST IRON STOVE MODEL OS10 3 WOLF STEEL LTD RR 1 24 NAPOLEON RD BARRIE ON CANADA L4M 4Y8 705 721 1212 Fax 705 722 6031 Email ASK NAPO...

Страница 2: ...eiling cavity or from an enclosed area such as an attic a basement or a garage Do not use this stove if any part has been under water immediately call a qualified service technician to inspect the sto...

Страница 3: ...warranty further does not cover any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts nor any venting components...

Страница 4: ...lemishes may result Normally a hot burn will clean the glass The most common reason for dirty glass is running the unit at a low burning rate If it is necessary to clean the glass use a soft cloth wit...

Страница 5: ...se segments work together to create the chimney draft To alter one of them will affect the other two and change the amount of draft in the chimney and ultimately the stove s performance To ensure that...

Страница 6: ...of the same make manufacturer as the chimney components Chimney installation Connection to a A VENT chimney An A Vent chimney either 4 101 6 mm or 5 127 mm in diameter may be used The minimum chimney...

Страница 7: ...he ash tray to the front of the oil stove tilt the tray at a 45 angle center onto tab A and lower into place Fitting the visioflamme optional Figure 9 Slide each glass piece so that it fits into the u...

Страница 8: ...y an oil pressure regulator must be fitted close to the carburetor to mitigate the pressure in the feeder line The oil feeder line or oil supply line must be copper tubing with a minimum outside diame...

Страница 9: ...ion is complete and all necessary instructions have been followed When lit for the first time the stove will emit a slight odour for a few hours This is a normal temporary condition caused by the curi...

Страница 10: ...oor If the flame is too low the oil flow rate should be increased by turning the set screw C on the carburetor counter clockwise If the flame is too high turn the screw clockwise The flames should hav...

Страница 11: ...YEARLY CHIMNEY MAINTENANCE The chimney is to be swept at least once a year It is also recommended that prior to every heating season the entire system be professionally inspected cleaned and repaired...

Страница 12: ...11 142412 Gasket A B C D 01 12 149868 Knob A B C D 01 13 158541 Handle A B C D 01 14 164205 Tightness nut A B C D 02 15 165324 Regulator A B C D 01 16 179605 Regulator shaft A B C D 01 17 181604 Ceram...

Страница 13: ...4 1 6 2 0 2 4 4 2 1 7 1 8 3 5 4 8 2 2 4 3 6 3 0 4 1 1 3 2 7 3 1 3 2 4 3 1 3 3 3 5 9 1 0 1 8 5 4 0 2 6 1 1 2 1 3 9 4 4 4 9 5 0 5 3 5 1 4 7 2 8 3 8 4 5 3 4 3 7 4 6 4 5 5 5 7 5 9 5 8 5 2 2 9 5 5 2 3 3 1...

Страница 14: ...45 325304 77 Reducing plate C 01 45 325304 79 Reducing plate A 01 45 325304 EF Reducing plate D 02 46 327801 Clamp A B C D 01 47 327901 76 Tray B 01 47 327901 77 Tray C 01 47 327901 79 Tray A 01 47 32...

Страница 15: ...Document n 1092 1 EN 04 02 2002 15 Notes...

Страница 16: ...scaler the carburetor filter and burner pot are cleaned Fire smokes Soot build up noticed Flame imbalance Insufficient air supply increase fresh air supply open door window add make up air supply Down...