User Manual
E727T0005, valid for E-727
BRO, 2019-06-28
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany
Page 93 / 240
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email
Command Description
Notes
TAD?
Get ADC Value Of Input
Signal
Reports the current ADC value of the analog input,
dimensionless
TNS?
Get Normalized Input
Signal Value
Reports the resulting value for the analog input after the
electronics linearization, dimensionless
TSP?
Get Input Signal
Position Value
Reports the resulting value for the analog input after the
mechanics linearization (scaling), the unit is µm
WPA
Save Parameters To
Nonvolatile Memory
Can be used to save the currently active configuration
(including analog input usage) to nonvolatile memory,
where it becomes the power-on default.
See "How to work with the Analog Input - Overview" (p. 85) for more information. For detailed
command descriptions see the GCS commands manual PZ281E. For the identifiers of the items
which can be addressed with the commands see " Axes, Channels, Functional Elements " (p. 22).
See " Parameters" (p. 185) for more information regarding the controller parameters and their
handling.
Parameter
ID
CCL for
write
access
Item Type
Concer-
ned
Max.
No. of
Items
Data
Type
Parameter
Description
0x02000200 1
Input Signal
Channel
7
FLOAT Sensor Mech. Correction 1 (Offset)
0x02000300 1
Input Signal
Channel
7
FLOAT Sensor Mech. Correction 2 (Gain)
0x05000000 1
Input Signal
Channel
7
INT
Digital Filter Type
0x05000001 1
Input Signal
Channel
7
FLOAT Digital Filter Bandwidth
0x05000002 1
Input Signal
Channel
7
INT
Digital Filter Order
0x06000500 1
Logical Axis 3
INT
ADC Channel for Target; if 0, then the
analog control input is disabled for the
axis
0x06000501 1
Logical Axis 3
FLOAT Analog Target Offset
0x07000500 1
Logical Axis 3
FLOAT Position from Sensor 1
0x07000501 1
Logical Axis 3
FLOAT Position from Sensor 2
0x07000502 1
Logical Axis 3
FLOAT Position from Sensor 3
0x07000503 1
Logical Axis 3
FLOAT Position from Sensor 4
0x07000504 1
Logical Axis 3
FLOAT Position from Sensor 5
0x07000505 1
Logical Axis 3
FLOAT Position from Sensor 6
0x07000506 1
Logical Axis 3
FLOAT Position from Sensor 7
0x0e000b00 3
System
1
INT
Number of input channels
0x0e000b03 3
System
1
INT
Number of sensor channels