Application examples for multifunctional PSRmultifunction safety relays
102597_en_03
PHOENIX CONTACT
Notes on theapplication
example
1.
The emergency stop control device is positive opening in accordance with EN 60947-5-1.
2.
The magnetic safety switch must meet the requirements of EN 60947-5-3.
3.
Contactors K5 … K8 have mirror contacts in accordance with EN 60947-4-1.
4.
Stop category 0 describes an immediate stop by removal of power by interrupting a
machine or drive element in accordance with EN 60204-1.
5.
When using the safety relay, take into consideration the maximum permissible number
of cycles for observing the SIL/PL safety characteristics in the specific application. The
safety characteristics can be found in the AH EN SAFETY CHARACTERISTICS appli-
cation note or the SISTEMA library.