Application manual for PSRclassic and PSRmultifunction, and the modular safety relay system
PHOENIX CONTACT
102597_en_03
5.2.2
PSR-ESD/4x1/30 up to PL e/SIL 3
Two-channel light grid monitoring with manual reset (ESPE type 4)
Application example
–
Two-channel light grid monitoring
–
Cross-circuit detection via the light grid
–
Manual reset (A1, S34)
–
Feedback of contactor contacts K5 and K6 at S34
–
Stop category 0
–
Monitoring of external contactors
–
Safety level of the example up to PL e (EN ISO 13849-1) and SIL 3 (EN 62061)
Figure 5-10
Two-channel light grid monitoring with manual reset
PSR-ESD/4x1/30
Order No.
2981800 with screw connection
2981813 with spring-cage connection
Technical data
–
24 V DC
–
2 undelayed enabling current paths, 2 delayed enabling
current paths
–
Adjustable delay time (0 s … 30 s)
–
Manual start or autostart
–
Basic insulation
–
Cat. 4/PLe in accordance with EN ISO 13849-1, SILCL 3 in
accordance with EN 62061
K
5
K
6
M
OSSD1 OSSD2
K
6
M
(N)
(
L
1)
K
5
L+
S11
S12
S21
S22
13
23
37
14
24
38
47
48
(
)
<
0
,
1
0
,
5
1
3
5
10
20
30
(
)
A
1
A
2
S34
PSR
-E
SD/4x1/30
S35
(
)
(
)
K
5
K
6
S2
Li
ght
gr
i
d
type
4
Transm
i
tter
Rece
i
ver
Reset
(C
l
ock)
(C
l
ock)