Application examples for multifunctional PSRmultifunction safety relays
102597_en_03
PHOENIX CONTACT
6.1.2
PSR-MXF2/4X1/2X2/B up to PL e/SIL 3
Two-channel, non-equivalent safety door monitoring with manual reset and higher-
level emergency stop monitoring
Application example
–
Two-channel, non-equivalent safety door monitoring
–
Manual start (S34, S36)
–
Feedback of contactor contacts K5 and K6 at S34
–
Feedback of contactor contacts K7 and K8 at S36
–
Stop category 0
–
Safety level of the example up to PL e (EN ISO 13849-1) and SIL 3 (EN 62061)
Figure 6-3
Two-channel, non-equivalent safety door monitoring
PSP-MXF2/4X1/2X2/B
Order No.
2903254 with screw connection
2902755 with spring-cage connection
2903256 with Push-in connection
Technical data
–
24 V AC/DC
–
4 enabling current paths, 2 signaling current paths
–
Monitored manual start or autostart
–
Basic insulation
–
Cat. 4, PL e in accordance with EN ISO 13849-1, SILCL 3 in
accordance with EN 62061
S4
S3
S5
K
5
K
6
K
7
K
8
K
6
K
5
K
8
K
7
N
K
5
K
6
M
K
7
K
8
M
+
24
V
DC
11 12 13 14
13 23
43 53
A
2
A
2 S34 S35 S36 S37
(
)
(
)
(
)
(
)
K
1
K
2
K
3
K
4
A
1
S11 S21
I
1
I
2
I
3
I
4
I
5
I
6
14 24 32
44 54 62
PSR
-...-
24DC/
MXF
2/4x1/2x2/B
S0
S1
S2
11 12 13 14
L
(
E
mergency
stop)
E
mergency
stop
Содержание 2702924