Do not touch or contact the input/output terminals because they may cause electric shock.

• Before you use, read safety precautions carefully, and use this product properly.
• Do not touch or contact the input/output terminals because they may cause electric shock.
•  If  you  are  concerned  about  serious  accident  due  to  the  malfunction  of  products, 

please install the external safety equipment

•  To prevent defection or malfunction of this product, supply proper power voltage in 

accordance with the rating.

•  To  prevent  electric  shock  or  devise  malfunction  of  this  product,  do  not  supply  the 

power until the wiring is completed.

•  Reassemble this product while the power is off. Otherwise, it may cause malfunction 

or electric shock.

•  If  the  user  use  the  product  with  methods  other  than  specified  by  the  manufacturer, 

there may be bodily injuries or property damages.

•  Due to the danger of electric shock, use this product installed onto a panel while an 

electric current is applied.

•  Before using the product you have purchased, check to make sure that it is exactly 

what you ordered.

•  Do not use this product at any place with corrosive
    (especially noxious gas or ammonia) or flammable gas.
•  Do not use this product at any place with liquid, oil, medical substances, dust, salt or 

iron contents.

•  Do not use this product at any place with excessive induction trouble, static electricity 

or magnetic noise.

•  Do not use this product at any place with possible thermal accumulation due to direct 

sunlight or heat radiation.

•  When the product gets wet, the inspection is essential because there is danger of an 

electric leakage or fire.

• Do not connect anything to the unused terminals.
• For DC types, connect wires at the correct position after checking polarity of terminal.
• The rated heat sink must be used otherwise, the product may be destroyed.
• When product is disposed, treat as a industrial waste.
• Since a heat sink corner is sharp, it would lead to a serious injury.
    when  electricity  flows,  desktop  or  heat  sink  temperature  would  be  high  so  that  it 

could lead people to suffer burns.

•This model has epoxy molding for the purpose of safety, reliability and extends of the life.
•When it is out of order, please separate SSR from head sink and only change SSR.
• When applying an electric current, SSR is heated more and more. So, it has more durable 

at low heat sink temperature and ambient temperature. 

DANGER

WARNING

CAUTION

Suffix code

Model

Code

Information

HSR-3SL

   

Slim Type 3-Phase Solid State Relay

Input Operating Voltage D

4 - 32 V DC

Rated load current

15

15 A

25

25 A

40

40 A

Rated load voltage

2

90 - 264 V AC (Low voltage)

4

90 - 480 V AC (High voltage)

Operation method
(Switching Mode)

Z

Zero Cross Switching (Standard product)

R

Random Switching

Specification

Dimension

Model

Low

HSR-3SLD152Z

HSR-3SLD252Z

HSR-3SLD402Z

High

HSR-3SLD154Z

HSR-3SLD254Z

HSR-3SLD404Z

Load

Rated Load 

Voltage

Low

90 - 264 V AC

High

90 - 480 V AC

Peak Voltage

(Non-repetition)

Low

600 V

High

800 V

1,200 V

Rated load current

15 A

25 A

40 A

Frequency

50/60 ㎐ (Dual usage)

Surge current

(8.3 ms No repetition)

Low

170 A

260 A

420 A

High

170 A

250 A

370 A

Leakage current

20 ㎃ max

Output ON voltage dropping

1.6 V (R.M.S) max

Input

Rated Voltage

5 - 24 V DC

Operating Voltage Range

4 - 32 V DC

Impedance

Less than 4 ㏀

Operation Voltage

More than 3 V DC

Reset Voltage

Less than 1.5 V DC

Input Current

Constant-current system : 10 ㎃ (±3)

Response Time

1/2 Cycle + 1 ms max. (“R”type below 1 ms)

Insulating Resistance

500 V DC,  100 ㏁ (Between the input / output and case) 

Dielectric strength

 3,000 V AC (For 1 min at 60 ㎐)

Vibration resistance

10 - 55 ㎐, Double amplitude : 1.5 ㎜, X,Y, and Z direction for 2 hours

Shock resistance

1,000 ㎨, X,Y,Z each axis 3 times

Storage Temperature

-30 ~ 90 ℃ 

Ambient Temperature

0 ~ 25 ℃ (But without frostiness)

Ambient Humidity

45 ~ 85 % R.H.

Weight

Approx. 1,000 g

Approx. 1,300 g

[Unit : mm]

※ Weight included the weight of box

▒ 15 A, 25 A

▒ 40 A

MC0601KE140227

28, Gilpa-ro 71beon-gil, Nam-gu, Incheon, Korea
TEL : (82-32)876-4697     FAX : (82-32)876-4696
http://www.hynux.com

HANYOUNGNUX CO.,LTD

HEAD OFFICE

JL.CEMPAKA BLOK F 16 NO.02 DELTA SILICON II INDUSTRIAL PARK 
LIPPO CIKARANG CICAU, CIKARANG PUSAT, BEKASI INDONESIA 17550
TEL : 62-21-8911-8120~4  FAX : 62-21-8911-8126 

PT. HANYOUNG ELECTRONIC INDONESIA

INDONESIA

FACTORY

 

Slim Type

 

HSR-3SL

     

3-Phase Solid State Relay

        

 

        Thank you for purchasing HANYOUNG product.
        Please check whether the product is the exactly same as you ordered. 
        Before using the product, please read this instruction manual carefully.
        Please keep this manual where you can view at any time

 

 INSTRUCTION MANUAL

DANGER indicates an imminently hazardous situation which, if 
not avoided, will result in death or serious injury

WARNING indicates a potentially hazardous situation which, if 
not avoided, could result in death or serious injury

CAUTION indicates a potentially hazardous situation which, if 
not avoided, may result in minor or moderate injury

DANGER

WARNING

CAUTION

Before using the product, please read the safety information thoroughly and use it properly. 
Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality

● HSR-3SL 외형 및 패널 가공치수 (단위:mm)

- 15A,25A 

- 40A -

96.6

87.6

4.

5

20.5

10.0

(43.1)

44.5

79.0

4.5

6.5

13.8

146

74.0

120

74

96.6

87.6

4.

5

20.5

10.0

(43.1)

44.5

95.0

4.5

6.5

13.8

● HSR-3SL 외형 및 패널 가공치수 (단위:mm)

- 15A,25A 

- 40A -

96.6

87.6

4.

5

20.5

10.0

(43.1)

44.5

79.0

4.5

6.5

13.8

146

74.0

120

74

96.6

87.6

4.

5

20.5

10.0

(43.1)

44.5

95.0

4.5

6.5

13.8