background image

Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may caus harmful interference to radio communications.However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment
should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D'INDUSTRIE CANADA
Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.
Son utilisation est soumise aux deux conditions suivantes :

ZW11 Z-Wave Mutil-relay Manual

ZW11 Z-Wave Mutil-relay

Son utilisation est soumise aux deux conditions suivantes :
(1) il ne doit pas provoquer d'interférences gênantes et
(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.

WARRANTY

Evalogik Products warrants this product to be free from manufacturing defects for 

a period of two years from the original date of consumer purchase. This warranty is limited 

to the repair or replacement of this product only and does not extend to consequential or

incidental damage to other products that may be used with this product.

 

This warranty is in lieu of all other warranties, expressed or implied. Some states do not 

allow limitations on how long an implied warranty lasts or permit the exclusion or limitation

 of incidental or consequential damage, so the above limitations may not apply to you. 
This warranty gives you specific rights, and you may also have other rights which vary from 

state to state. if the unit should prove defective within the warranty period.

SPECIFICATIONS  

WARNING

Model:ZW11

RISK OF FIRE

Power:DC5V /AC12-24V.

RISK OF ELECTRICAL SHOCK

Signal (Frequency): 908.42 MHZ.

RISK OF BURNS

Maximum load    R1/R2  250 V / 15A*2  

CONTROLLING APPLIANCES:

                           R3        250V/20A

EXERCISE EXTREME CAUTION WHEN USING Z-Wave DEVICES TO CONTROL 
APPLIANCES. OPERATION OF THE Z-Wave DEVICE MAY BE IN A DIFFERENT

Range: Up to 100 feet line of sight between the Wireless Controller

ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION

and the closest Z-Wave receiver module.

 MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave DEVICES

Operating Temperature Range: 32-104° F (0-40° C)

MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING. 
 DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL 

Specifications subject to change without notice

OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE

due to continuing product improvement

 REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE

 

THE FOLLOWING:

Website:www.nie-tech.com

DO NOT USE Z-Wave DEVICES TO CONTROL ELECTRIC

 

HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT

 

A HAZARDOUS CONDITION DUE TO UNATTENDED OR

 

UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Содержание ZW11

Страница 1: ...sation est soumise aux deux conditions suivantes ZW11 Z Wave Mutil relay Manual ZW11 Z Wave Mutil relay Son utilisation est soumise aux deux conditions suivantes 1 il ne doit pas provoquer d interférences gênantes et 2 il doit tolérer les interférences re ues notamment cellessusceptibles d en perturber le fonctionnement WARRANTY Evalogik Products warrants this product to be free from manufacturing...

Страница 2: ...existing Z Wave home control network with your primary controller Refer to your primary controller instructions to process the inclusion exclusion setup procedure Include ZW11 to from a Z Wave Gateway with supporting Security The ZW11 can support the Primary Controller that implemented the security S2 Notice Including a node ID allocated by Z WaveTM Controller means Add or Inclusion Excluding a no...

Страница 3: ...ASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_SWITCH_BINARY ZW11 protocol Endpoint 3 Full Command Class Node Info COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_SECURITY_2 The Below listed Command Class are all supported the Security S2 COMMAND_CLASS_...

Страница 4: ... No 14 0x0E Size 1 Byte Value 00 manual control disabled Value 01 manual control enabled default Support for Association Groups ZW11 supports 4 association groups Group 1 support 1 node ID Group 2 3 4 Support maximum of 5 node ID s Group 2 Mapping to EP 1 Association Group 2 Group 3 Mapping to EP 2 Association Group 2 Group 4 Mapping to EP 3 Association Group 2 Association group_1 Z Wave Plus Life...