Philadelphia Scientific
®
iBOS
®
Pro 6 Series Installation Manual
Page 66 of 84
Shouter Sounds
when user selects the battery
indicated on the display
Check the SBC connector on the charger
and on the battery. A loose connector can
cause in intermittent contact.
Make sure that the sign on the battery slot
matches the charger ID programmed in the
control box. To do this, connect the battery to the
charger and then look at the LCD display in the
control box. It should indicate that a battery
connect happened and will show the charger ID.
Make sure the charger ID matches.
Shouter Sounds
when battery is connected
This can happen when the connection is made
and broken several times while the operator is
connecting. Often this is due to loose connectors
that sometimes are in need of repair or
replacement. Sometimes it is due to a stiff
connection where the user has to wiggle the
connector to get it to go on.