Task
Status
Make sure all Sentinels
™ are displaying a solid green light.
Test the Shouter(s) for
“Correct” and “Incorrect” battery pick sounds from the
menu. Test this by clicking “Settings” then “Volume.” Also select desired volume
at this time.
Test the upload capabilities of the iBOS
®
System via the Internet.
If the passwords were disabled during installation, reset the Maintenance default
password to “11111” and the Settings default password to “919191”. Or set
passwords of your own choosing.
Make sure the date and time are set correctly.
Make sure all chargers are labeled by Pool (101, etc.)
Check Charger Settings to make sure “Cool Down” setting and “Delay
Equalization Charge” are set to “Off.”