Philadelphia Scientific
®
iBOS
®
Pro 6 Series Installation Manual
Page 64 of 84
8.3 Sentinel
™
Check connection to the input
socket on the sentinel
Yes
No
LED’s not lighting
up
Is the Controller on?
Green LED is
flashing
CHARGER NO
START
– Amber LED
Flashing
Connected for more than 5
minutes (charger didn't start)
Verify all Charger
systems (Fuses, AC
Power, Circuit Boards)
and check battery
capacity.
Slow Flash
(1/sec)
Indicates the Sentinel is registered
with the controller but has not received
or has lost the assigned voltage
Charger shows in
queue but charger
is still charging
This may also appear
on the Scrolling
Display as a battery
to take
Check Charger
programmed settings,
some chargers are set to
force a cool down by
appearing to still be
charging a battery
Modify CHARGER
SETTINGS if
needed.
Battery was taken as
indicted by Display
but truck/pallet jack
gauge showed
“EMPTY”
Verify truck/pallet jack
calibration is correct
based on battery fleet
needs
Verify VPC on
battery, look for weak
cells or low acid
CALL TRUCK
SERVICE
COMPANY
Charger may be in a
Refresh charge
Push STOP on
charger and take
battery
SCORE CARD:
Charger “Not
Reporting In”
Check Sentinel
Sentinel has no
power (
no LED’s
are on)
Sentinel has power
(
LED’s are on)
Verify Charger is
operational, trouble
shoot charger
Check Upstream
Sentinel is lit.
For assistance,
Contact
Philadelphia Scientific
Customer Service
Check Cable to sentinel is CAT3
and passes the straight through
wire test.
No
Was there a Charger
No Start? Check
charger function.
Fast Flash
(>1/sec)
Slow Flash
(1/sec)
Fast Flash
(>1/sec)
Indicates the Sentinel is not
registered but is getting power.
Connected for more than 7
days with no charger activity
Connect a Battery if
still flashing check
quick tap
Verify Pins are
straight. If bent,
straighten and
reinstall at new
location
Sentinel is powered
by control box,
check power to the
bus on the control
box.
Sentinel still not
functioning
Yes
Ensure Pool Voltage is
set in the control box.
Settings/Pool &
Chargers
Check
connection to
the input socket
on the sentinel
Check Cable to
sentinel is CAT3
and passes the
straight through
wire test.
See Appendix A for further information on Sentinels
™
.