7. Final Inspection and Testing
7.1 Sentinels
™
If you have successfully run the
installation wizard for all of the
Sentinels
™, then the green LED is solid
on each Sentinel
™.
If you want to double check the
connection, you can disconnect a battery
from a charger and then watch the system
status screen. You should see the
charger ID. If you don’t see the pool and
charger ID you expected, then the system
may be misconfigured.
The charger ID will move from column to
column as the status changes.
Note: a 10 charger pool you should see
all 10 charger IDs.
Available = Charged and ready to use.
The top of the queue is 102 and this
charger ID will be the Next Battery on the
Scrolling Display or on home screen.