Care and maintenance
12 - 4
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
Fig. 12 - 04
12
.05
Cleaning the filter of the air filter/regulator
Switch the machine off!
Disconnect the air hose at the
air filter/regulator unit.
Emptying water bowl
1
:
●
Water bowl
1
empties itself automatically
when the air hose is disconnected from
the air filter/regulator.
Cleaning filter
2
:
●
Unscrew water bowl
1
.
●
Take out filter
2
.
●
Clean filter
2
with compressed air or
isopropyl alcohol
(part No. 95-665 735-91).
●
Screw in filter
2
and screw on water
bowl
1
.
Fig. 12 - 05
2
1
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
1
2
12
.04
Checking and adjusting the air pressure
●
Check the air pressure on gauge
1
every
time before operation.
●
Gauge
1
must show a pressure of
6
bar.
●
If necessary, adjust to this setting.
●
To do so, lift knob
2
and turn it until the
guage shows a pressure of
6 bar.