Installation and commissioning
8 - 2
0
2
4
6
8
10
12
14
16
0
50
100
150
200
250
8
.02
Commissioning
The machine must only be connected to a suitably earthed socket!
●
Clean the machine thoroughly and check
the electric wiring and pneumatic tubes
for any damage.
●
Oil the machine, or top up the oil (see
Chapter 12, Care and maintenance).
●
Have the machine connected to the
electric mains by qualified personnel,
making sure that the machine can really
be used with the available mains
voltage.
If there is any discrepancy, do not put
the machine into operation!
●
Connect the machine to the compressed
air supply.
●
Gauge
1
must then indicate a pressure
of 6 bar.
●
If necessary, adjust this setting on
adjusting knob
2
.
Fig. 8 - 02
2
1
0
2
4
6
8
10
12
14
16
0
50
100
150
200
250
8
.03
Switching the machine on or off
●
Check air presure on gauge
1
and adjust
pressure on adjusting knob
2
if
necessary.
●
Turn main switch
3
to the "ON" position.
The machine is automatically set in the
INPUT
mode.
●
To switch off the machine turn main
switch
3
to the "OFF" position.
2
1
Fig. 8 - 03
3