10 - 9
Programming
6 - SWITCHING OF INPUTS
In this function, after the code number is selected and verified with the enter key, the
corresponding output can be selected with
number key 1
and reset with
number key 0
.
Code number Terminal
Output board
Output
Function
8
1
A25
Y1.1
Guide blade back
Y12
Guide blade pressure (only
with feed table)
9
2
Y1.2
Guide blade forward
Y1
Guide blade forward (only
with feed table)
10
3
Y2
Guide blade right
11
4
Y3
Work holder up
12
5
Y4
Airblast on
13
6
Y5
Thread trapper on
14
7
Y6
Thread trapper up
15
8
K7
Thread trim on
(only on PFAFF 3566-2/02)
16
9
-
free
17
10
-
free
18
11
Y10
Thread tension release on
19
12
Y11
Small-part stop back
20
13
Y13
Brake for engaging depth
(only with feed table)
21
14
-
free
22
15
-
free
23
16
Y15
Suction on (only with feed table)
0
17
L14.1
Stepping motor, engaging depth, coil 1
1
18
L14.2
Stepping motor, engaging depth, coil 2
2
19
L14.3
Stepping motor, engaging depth, coil 3
3
20
L14.4
Stepping motor, engaging depth, coil 4
4
21
-
free
5
22
Y7
Bobbin-thread monitor reset
(only on PFAFF 3566-3/02)
6
23
BOBRES
Reset für Unterfadenwächter
7
24
REF
Reference output for needle in
material
Special commands:
24
5
Y4
Airblast function (timed reset)
7 - SOFTWARE DATE
When this function is enabled, the date of the control software (CPU) is indicated.