ELECTRICITY
77
Reproduction or translation, even partial, is forbidden without the written consent of Peugeot Scooters
Checking the indicators
- Removing an indicator.
- Connect the indicator in series with a battery
and a ammeter.
Normal consumption: 0.30 - 0.40 A.
- If consumption is outside this range, change the
indicator.
- Carry out the same operation with the other
indicators.
- If the consumption of the indicators is correct,
check the wiring harness.
Checking the red light, the stop light and
the side light
- Remove the side light or the rear light.
1. Connect the side light in series with a
battery and an ammeter.
Normal consumption: 0.25 - 0.35 A.
2. Connect the stop light in series with a
battery and an ammeter.
Normal consumption: 0.25 - 0.35 A.
3. Connect the red light in series with a battery
and an ammeter.
Normal consumption:
0.60 - 0.70 mA.
- If the consumption is outside this range, change
the side light or the rear light.
- If the consumption of the side light or the rear
light is correct:
Check:
• The main harness.
• The stop light contactors.
• The magneto.
• The regulator.
-
+
OFF
V
DC
V
AC
Ω
20 m
200 m
DC
10A
V
Ω
COM
mA
A
-
+
OFF
V
DC
V
AC
Ω
20 m
200 m
DC
10A
V
Ω
COM
mA
A
3
2
1