AS-i/PROFIBUS-Gateway
Command Interface
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com
Is
s
ue dat
e -
12.
8.
2007
91
Meaning of bit B:
B = 0Single AS-i slave or A-slave
B = 1B-slave
10.3.5.5
Set permanent configuration (SET_PCD)
This call sets the following configuration data for the addressed AS-i slave:
• I/O configuration
• ID code
• Extended ID1 code
• Extended ID2 code
The configuration data are stored permanently on the EEPROM of the AS-i/
PROFIBUS gateway and are used as the expected configuration by the AS-i mas-
ter in the protected mode. The configuration data are specified by the manufactur-
er of the AS-i slave.
If the addressed AS-i slave does not support an extended ID code 1/2, the value
F
hex
must be specified.
When this command is executed, the AS-i master changes to the offline phase and
then changes back to the normal mode (warm restart).
This command can only be executed in the configuration mode.
Meaning of bit B:
B = 0Single AS-i slave or A-slave
B = 1B-slave
Response
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
28
16
2
T
result
3
xID2
xID1
4
ID
I0
Request
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
25
16
2
T
–
circuit
3
–
B
slave address
4
xID2
xID1
5
ID
I0
Response
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
25
16
2
T
result