AS-Interface
Appendix: Codes indicated by the Display
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com
Is
s
ue dat
e -
12.
8.
2007
160
82
The front panel operation is blocked. Until repowering-up the device can
only be accessed from the host via the interface.
83
Program reset of the AS-i Control programm: The AS-i Control programm
is being read out of EEPROM and copied into the RAM.
88
Display test while starting up the AS-i master
90
Error while changing a slave address in protected operating mode: No
slave with address 0 existing.
91
Error while changing slave address: Target address is already used.
92
Error while changing slave address: New address could not be set.
93
Error while changing slave address: New address could only be stored
volatilely in the slave.
94
Error while changing the slave address in protected operating mode:
Slave has wrong configuration data.
95
The error 95 is caused by a superfluous slave and not by a missing slave.
That is why the slave address is ocupated by this superfluous slave.
(In the protected mode the slave addresses which caused any configura-
tion error can be displayed by pressing the SET button. AS-i master without
graphical display are not able to differentiate between a missing slave, an
incorrect slave or a redundant slave. All incorrect addresses are displayed.
By pressing the SET button 5 sec. the displayed address starts to flash.
Pressing the SET button again the master attempts to program the slave at
the address 0 to the incorrect address.)