![Pepperl+Fuchs ICE1 G60L-C1-V1D Series Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/pepperl-fuchs/ice1-g60l-c1-v1d-series/ice1-g60l-c1-v1d-series_manual_1527934091.webp)
ICE1-*-G60L-V1D, ICE1-*-G60L-C1-V1D
Commissioning for EtherCAT
2
0
1
9
-1
0
91
•
0x2304:0B (X6A) = 10 for the 16DI/DO profile means that input bit X6A is assigned to pro-
ducing bit 10 (byte 1/bit 2) and that the output bit of consuming byte 1/bit 2 is used as out-
put control information for port X6A.
Example of process data in the
bit
format:
•
0x2304:0B (X6A) = 10 for the 16DI/DO profile means that input bit X6A is assigned to pro-
ducing bit 10 and that the output bit of consuming bit 10 is used as output control informa-
tion for port X6A.
7.2.6
Configuration Example with TwinCAT
®
3
The configuration and commissioning of the modules described below refers to the software
TwinCAT
®
3 from Beckhoff Automation GmbH.
The configuration is based on the example of an ICE1-16DIO-G60L-V1D module. For other
module versions, configuration is carried out with a few minor changes.
If you have a control system from a different provider, please refer to the corresponding docu-
mentation from the provider.
Integrating the PLC
1.
Install the ESI file of the module family in TwinCat
®
. In TwinCAT
®
3, the ESI file is normally
inserted in the installation folder
C:\TwinCAT\3.1\Config\Io\EtherCAT
.
After you restart TwinCAT
®
, the modules will be available in the hardware catalog.
2.
Start TwinCat and open a new project.
3.
Select the "SYSTEM" option in "Solution Explorer" and click on the "Choose Target
”
button.
Caution!
Personal injury and property damage
Before you adjust the inputs or outputs of the module, make sure that no personal injury or
property damage can occur.
Note
After creating the project, you must first take the following steps to establish
communication with the PLC.