ICE1-*-G60L-V1D, ICE1-*-G60L-C1-V1D
Commissioning, Protocol Setting
2
0
1
9
-1
0
17
4
Commissioning, Protocol Setting
4.1
Setting Protocols
Multiprotocol
You can use the multiprotocol modules to select various protocols for communication within a
fieldbus system. This allows you to integrate the multiprotocol modules into different networks
without having to obtain a specific module for each protocol. This technology also allows you to
use the same module in different environments. Using the rotary switches on the front of the
modules, you can easily and conveniently set the protocol and address of the module if the pro-
tocol to be used supports this. Once you have selected a protocol and started the cyclical com-
munication, the module recognizes these settings and uses the selected protocol from this
point on. To use another supported protocol with this module, perform a factory reset.
Setting a Protocol
Multiprotocol modules have a total of three rotary switches. Alter the switch position for the first
rotary switch X100 to set the protocol. For the other rotary switches, set the last two digits of the
IP address when using EtherNet/IP.
Figure 4.1
Rotary switch X100
Assigning the Protocol Using the Rotary Switches
The default settings of the module do not contain any protocol settings. In this case, simply
select the desired protocol. To use a modified rotary switch setting (protocol setting), you have
to execute a power cycle or "Reset" of the web interface. Once you have set the protocol using
the rotary switches, the module saves these settings as soon as it starts a cyclical communica-
tion. From this point, you can no longer change the protocol using the rotary switch. To change
the protocol, perform a factory reset first.
If you set the rotary coding switch to an invalid position, the device signals this with a flash
code: the BF/MS/ERR LED flashes red three times.
You can change the IP address depending on the selected protocol.
Protocol
X100
X10
X1
EtherNet/IP
0-2
0-9
0-9
PROFINET
P
-
-
EtherCAT
EC
-
-
2
0
X
1
0
X
X03
X4
X8
7
X
3
X
X6
5
X
1
X
X2
A
DIA
B
XE
X04
BF
DIA
Lnk/Act
X02
X01
U
S
16DI
A
DIA
B
A
DIA
B
A
DIA
B
x100
x10
x1
MS NS
0 E/IP
P
0
0
9
EC
RUN ERR
FM
C
R
0
E/IP
P
EC
X100
9
Содержание ICE1 G60L-C1-V1D Series
Страница 1: ...R ICE1 G60L V1D ICE1 G60L C1 V1D Fieldbus Modules with Multiprotocol Technology Manual...
Страница 56: ...2019 10 56 ICE1 G60L V1D ICE1 G60L C1 V1D Commissioning for PROFINET Figure 6 15 1 2 3...
Страница 139: ...ICE1 G60L V1D ICE1 G60L C1 V1D Firmware Update 2019 10 139 Figure 10 4...