![Pepperl+Fuchs ICE1 G60L-C1-V1D Series Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/pepperl-fuchs/ice1-g60l-c1-v1d-series/ice1-g60l-c1-v1d-series_manual_1527934145.webp)
ICE1-*-G60L-V1D, ICE1-*-G60L-C1-V1D
Troubleshooting
2
0
1
9
-1
0
145
Content of the Diagnosis Register
Legend:
•
MI-LVS
: Module information byte
—
voltage for power/sensor supply low
•
MI-LVA
: Module information byte
—
voltage for actuator low
•
MI-SCS
: Module information byte
—
sensor short circuit on an M12 slot
•
MI-SCA
: Module information byte
—
actuator short circuit
•
MI-FC
: Module information byte
—
forcing active
•
MI-IME
: Module information byte
—
internal module error
•
CE-X1A ... CE-X8A
: Channel error, channel A (pin 4) of slots X1 to X8
•
CE-X1B ... CE-X8B
: Channel error, channel B (pin 2) of slots X1 to X8
The following example shows the error message received by a TwinCAT master regarding an
actuator voltage power fault:
Figure 11.3
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 4
MI-IME
MI-FC
0
0
MI-SCA
MI-SCS
MI-LVA
MI-LVS
Byte 5
SCS-X8
SCS-X7
SCS-X6
SCS-X5
SCS-X4
SCS-X3
SCS-X2
SCS-X1
Byte 6
CE-X4B
CE-X4A
CE-X2B
CE-X2A
CE-X2A
CE-X2A
CE-X1B
CE-X1A
Byte 7
CE-X8B
CE-X8A
CE-X7B
CE-X7A
CE-X6A
CE-X6A
CE-X5B
CE-X5A
Byte 8
0
0
0
0
0
0
0
0