ICE1-*-G60L-V1D, ICE1-*-G60L-C1-V1D
Commissioning for PROFINET
2
0
1
9
-1
0
49
Figure 6.6
2.
Check the automatically assigned IP address in "PROFINET interface [x1] -> Ethernet
addresses.
”
3.
Check whether control system and module are on the same Ethernet subsystem. If necessary,
change the setting.
Figure 6.7
4.
Activate the selection "Generate PROFINET device name automatically,
”
so that the device
name is that which was assigned previously.
Assigning the Device Name to a PROFINET IO Module
So that each node in the PROFINET network can be assigned an IP address, each module
must have a device name. A node search displays all PROFINET devices that have been
found.
On delivery, the Ethernet IO modules are assigned three MAC addresses. These are unique
and cannot be changed by the user. The first MAC address is shown on the housing of the
Ethernet IO module. (See between X2 and X3). Using this, each device can be found in the list
of available nodes and assigned a device name.
1.
Connect the module to the PROFINET network.
2.
In "Device View,
”
select the module "Slot 0.
”
Note
Using a modified device name is not recommended for clarity reasons.